Panasonic U-180PE2R8A Скачать руководство пользователя страница 2

2

z

z

Safety Precautions

 ........................................................... 2

z

z

Precautions for Use

 ......................................................... 4

z

z

Names of Parts

 ................................................................. 5

z

z

Operation

 .......................................................................... 5

• Operation Mechanism

 ................................................... 5

z

z

Maintenance

 ..................................................................... 6

• Before Requesting Services

 ......................................... 6

z

z

Troubleshooting

 ............................................................... 7

z

z

Specifications

 ................................................................... 8

• Indoor unit

 ...................................................................... 8

• Outdoor unit

 ................................................................... 9

Contents

Confirm to authorized dealer 

or specialist on usage of 

specified refrigerant type. Using 

of refrigerant other than the 

specified type may cause product 

damage, burst and injury etc.
This air conditioner has no 

ventilator for intaking fresh air 

from outdoors. You must open 

doors or windows frequently 

when you use gas or oil heating 

appliances in the same room, 

which consume a lot of oxygen 

from the air. 

Otherwise there is a risk of 

suffocation in an extreme case.
Never use or store gasoline or 

other flammable vapor or liquid 

near the air conditioner — it is 

very dangerous.
Do not use this appliance in a 

potentially explosive atmosphere.
Never touch the unit with wet hands.
Do not insert your fingers or 

other objects into the air 

conditioner indoor or 

outdoor unit, rotating parts may 

cause injury.

If the refrigerant comes in contact 

with a flame, it produces a toxic 

gas.
For safety, be sure to turn the 

air conditioner off and also to 

disconnect the power before 

cleaning or servicing.
Pull off the power plug from  

a receptacle, or switch off  

the breaker, or switch off the 

power disconnecting mean to 

isolate the air conditioner from 

the main power supply in case of 

emergency.
Do not clean inside the indoor and 

outdoor units by users. Engage 

authorized dealer or specialist for 

cleaning.
In case of malfunction of this 

appliance, do not repair by yourself. 

Contact to the sales dealer or 

service dealer for a repair.

Thank you for purchasing this Panasonic product.

This product is a commercial air conditioner indoor unit.

Installation Instructions attached.

Safety Precautions

Product Information

If you have problems or questions concerning your Air 

Conditioner, you will need the following information. Model and 

serial numbers are on the nameplate.

Model No. 

Serial No. 

Date of purchase

Dealer’s address

Phone number

The following symbols used in this manual, alert you to 

potentially dangerous conditions to users, service personnel or 

the appliance:

WARNING

This symbol refers to a hazard or 

unsafe practice which can result in 

severe personal injury or death.

CAUTION

This symbol refers to a hazard or 

unsafe practice which can result 

in personal injury or product or 

property damage.

Prohibited matters

Matters to be  

observed

• Read these Operating Instructions carefully before using this 

air conditioner. If you still have any difficulties or problems, 

consult your dealer for help.

• This air conditioner is designed to give you comfortable 

room conditions. Use this only for its intended purpose as 

described in these Operating Instructions.

WARNING

01_281298_EU_En.indb   2

2016-7-1   14:40:34

Содержание U-180PE2R8A

Страница 1: ...it read these operating instructions thoroughly and keep them for future reference Model No INDOOR UNIT High Static Pressure Ducted Type E2 S 180PE2R5B S 200PE2R5B S 224PE2R5B OUTDOOR UNIT Single Split Type PE2 U 180PE2R8A U 200PE2R8A U 224PE2R8A High Static Pressure Ducted Type E2 CV6233332949 01_281298_EU_En indb 1 2016 7 1 14 40 33 ...

Страница 2: ... power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency Do not clean inside the indoor and outdoor units by users Engage authorized dealer or specialist for cleaning In case of malfunction of this appliance do not repair by yourself Contact to the sales dealer or service dealer for a repair Thank you for purchasing this Panasonic product This produc...

Страница 3: ...s To prevent possible hazards from insulation failure the unit must be grounded Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power switch and breaker Risk of smoke fire electric shock Examples of abnormality failure The ELCB trips freque...

Страница 4: ...witch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time Operation Condition Use this air conditioner under the following temperature range Indoor temperature range Cooling mode 18 C 32 C DBT Heating mode 16 C 30 C DBT Outdoor temperature range Cooling mode 15 C 46 C DBT Heating mode 20 C 24 C DBT DBT Dry bulb temperature Info...

Страница 5: ... the outdoor unit repeats the cycle of turning on and off automatically z z When the outdoor unit is turned off the indoor unit fan will stop too To prevent the humidity in the room from rising again z z When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically z z DRY operation is not possible if the outdoor temperature is 15 ...

Страница 6: ...ed Contact your dealer Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode Lower the temperature setting If your air conditioner does not work properly even after checking each item of Before Requesting Services and Troubleshooting z z Stop the operation immediately and turn the power off Then contact your deale...

Страница 7: ...large amounts of oil mist exist cleaning is necessary because the unit inside heat exchanger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is rotating for a while even though operation stops Fan rotation makes operation smooth The fan may rotate to dry the heat exchanger depending on the setting Dust is discharged Dust accumulated inside t...

Страница 8: ... 200 76 400 Heating capacity kW 20 0 22 4 25 0 BTU h 68 200 76 400 85 300 Sound Pressure level High dB A 43 47 47 Medium dB A 41 45 45 Low dB A 38 42 42 Sound Power level High dB A 75 79 79 Medium dB A 73 77 77 Low dB A 70 74 74 Unit Dimensions H W D mm 479 1 453 1 205 479 1 453 1 205 479 1 453 1 205 Net weight kg 100 104 104 Indoor unit 01_281298_EU_En indb 8 2016 7 1 14 40 38 ...

Страница 9: ...ame U 180PE2R8A U 200PE2R8A U 224PE2R8A Power source 400 415 V 3N 50 Hz Cooling capacity kW 18 0 20 0 22 4 BTU h 61 400 68 200 76 400 Heating capacity kW 20 0 22 4 25 0 BTU h 68 200 76 400 85 300 Sound pressure level C H dB A 59 61 60 62 60 62 Sound power level C H dB A 77 79 79 81 79 81 Unit dimensions H W D mm 1500 980 370 1500 980 370 1500 980 370 Net weight kg 127 138 138 01_281298_EU_En indb ...

Страница 10: ...10 MEMO 01_281298_EU_En indb 10 2016 7 1 14 40 39 ...

Страница 11: ...11 MEMO 01_281298_EU_En indb 11 2016 7 1 14 40 39 ...

Страница 12: ...Panasonic Corporation Website http www panasonic com Printed in China Panasonic Corporation 2016 85464609359020 DC0716 0 01_281298_EU_En indb 12 2016 7 1 14 40 39 ...