1 Safety Precautions
1.1. General Guide
1. It is advisable to insert an isolation transformer in the AC
supply before servicing a hot chassis.
2. When servicing, observe the original lead dress, especially
the lead dress in the high voltage circuits. If a short circuit is
found, replace all parts which have been overheated or
damaged by the short circuit.
3. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers, shields and
isolation R-C combinations, are properly installed.
4. When the receiver is not to be used for a long period of
time, unplug the power cord from the AC outlet.
5. Potential, as high as
32.0
kV is present when this receiver
is in operation. Operation of the receiver without the rear
cover involves the danger of a shock hazard from the
receiver power supply. Servicing should not be attempted
by anyone
who is not thoroughly
familiar
with the
precautions necessary when working on high voltage
equipment. Always discharge the anode of the picture tube
to the receiver chassis before handling the tube.
6. After servicing make the following leakage current checks to
prevent the customer from being exposed to shock
hazards.
1.2. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Turn on the receiver’s power switch.
3. Measure the resistance value, with an ohmmeter, between
the jumper AC plug and each exposed metallic cabinet part
on the receiver, such as screw heads, aerials, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
4
M
Ω
Ω
Ω
Ω
and 20 M
Ω
Ω
Ω
Ω
. When the exposed metal does not have a
return path to the chassis, the reading must be infinite.
1.3. Leakage Current Hot Check
(See Fig. 1)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 2k
Ω
, 10 W resistor in series with an exposed
metallic part on the receiver and an earth such as a water
pipe.
3. Use an AC voltmeter, with high impedance type, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential any point should not exceed
1.0 V rms
. In the
case of a measurement being outside of the limits specified,
there is a possibility of a shock hazard, and the receiver
should be repaired and rechecked before it is returned to
the customer.
3
TX-29P180X
Содержание TX-29P180B
Страница 25: ...7 CONDUCTOR VIEWS 7 1 A Board TNP4G167AA 25 TX 29P180X ...
Страница 26: ...8 SCHEMATIC DIAGRAMS 8 1 SCHEMATIC DIAGRAM NOTES 26 TX 29P180X ...
Страница 27: ...27 TX 29P180X ...
Страница 29: ...9 PARTS LOCATION TX 29P180X 29 ...
Страница 30: ...TX 29P180X 30 ...
Страница 31: ...10 Replacement Parts List 10 1 Replacement Parts List Notes 31 TX 29P180X ...
Страница 32: ...10 2 Replacement Part List 32 TX 29P180X ...