8.2. Sub contrast adjustment (HDTV)
Preparation
PICTURE:VIVID (NORMAL SET)
ADJUSTMENT DATA: BRIGH, CONT
Measurement Instrument
Remarks
1.
Oscilloscope
2.
Alignment equipment
Extension cable kit (Part No.TZSC0704)
3.
Remote control
Picture menu: VIVID
Picture pattern: 10 stair-step
Adjustment Procedures
1.
Apply the HD 10 stair-step signal to HD baseband signal.
2.
Connect the Oscilloscope to CN3303-A38 (G out of DR-Board).
3.
Adjust Sub contrast so that B-W is 0.60V±0.02V.
4.
Also connect the oscilloscope to CN3303-A34 (R out) and observe both waveforms simultaneously.
5.
Adjust R-drive so that the amplitude of R signal waveform is same as G signal.
6.
Connect the Oscilloscope to CN3303-A38 (G out) and CN3303-A36 (B out), and observe the both waveforms simultaneously.
7.
Adjust B-drive so that the amplitude of B signal is same as G signal.
14
TU-PT700U