12
5.2.
Service tool mode
5.2.1.
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
5.2.2.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication will be cleared by [Self-check indication and forced to factory shipment setting].
5.2.3.
POWER ON Time, On/Off
Note : To display Time, On/Off menu, highlight position, then press MUTE for 3sec.
Time : Cumulative power on time, indicated hour : minute by decimal
On/Off : Number of On/Off switching by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
5.2.4.
Exit
1. Disconnect the AC cord from wall outlet or switch off the power with [ Power ] button on the main unit.
Содержание TH-P54S10M
Страница 17: ...17 6 4 No Picture ...
Страница 29: ...29 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Страница 34: ...34 ...
Страница 40: ...40 ...
Страница 42: ...42 11 3 Wiring 2 ...
Страница 43: ...43 11 4 Wiring 3 ...
Страница 44: ...44 ...
Страница 45: ...45 12 Schematic Diagram 12 1 Schematic Diagram Note ...
Страница 82: ...82 13 Printed Circuit Board 13 1 P P 1 Board A B C D E F G H I 1 2 3 4 5 6 P P 1 BOARD FOIL SIDE ETX2MM761MGN ...
Страница 84: ...84 A B C D E F G H I 1 2 3 4 5 6 P P 1 BOARD COMPONENT SIDE ETX2MM761MGN ...
Страница 98: ...98 14 1 2 Packing 1 ...
Страница 99: ...99 14 1 3 Packing 2 ...
Страница 100: ...100 14 1 4 Packing 3 ...
Страница 104: ...104 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...