1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
5. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
6. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When the
exposed metallic part has a return path to the chassis, the
reading should be 100 Mohm and over.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
1.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15
μ
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should
be repaired and rechecked before it is returned to the
customer.
Figure 1
Содержание TH-L32E30R
Страница 15: ...TH L32E30R 15 7 2 Control Panel Assembly Side AV Installation Control panel button into control panel bracket ...
Страница 22: ...TH L32E30R 22 7 9 Stand MTG Assembly Accessories Assembly Put all screw inside plastic bag ...
Страница 24: ...TH L32E30R 24 8 3 P Board Dummy jig for P PCB TNPA5364 checking Schematic ...
Страница 29: ...TH L32E30R 29 11 Schematic Diagram 11 1 Schematic Diagram Notes ...
Страница 30: ...TH L32E30R 30 11 2 A Board 11 2 1 A Board Sheet 002 1 2 1A 2A 3A ...
Страница 31: ...TH L32E30R 31 11 2 2 A Board Sheet 002 2 2 1A 2A 3A ...
Страница 32: ...TH L32E30R 32 11 2 3 A Board Sheet 003 1 5 1A 2A 3A ...
Страница 33: ...TH L32E30R 33 11 2 4 A Board Sheet 003 2 5 1B 2B 3B 1A 2A 3A ...
Страница 34: ...TH L32E30R 34 11 2 5 A Board Sheet 003 3 5 1C 1B 2B 3B ...
Страница 35: ...TH L32E30R 35 11 2 6 A Board Sheet 003 4 5 1C 1D 2D ...
Страница 36: ...TH L32E30R 36 11 2 7 A Board Sheet 003 5 5 1D 2D ...
Страница 37: ...TH L32E30R 37 11 2 8 A Board Sheet 004 1 2 1A 2A ...
Страница 38: ...TH L32E30R 38 11 2 9 A Board Sheet 004 2 2 1A 2A ...
Страница 39: ...TH L32E30R 39 11 2 10 A Board Sheet 005 1 2 1A 2A ...
Страница 40: ...TH L32E30R 40 11 2 11 A Board Sheet 005 2 2 1A 2A ...
Страница 41: ...TH L32E30R 41 11 2 12 A Board Sheet 006 1 1 ...
Страница 42: ...TH L32E30R 42 11 2 13 A Board Sheet 008 1 1 ...
Страница 43: ...TH L32E30R 43 11 2 14 A Board Sheet 009 1 1 ...
Страница 44: ...TH L32E30R 44 11 2 15 A Board Sheet 010 1 1 ...
Страница 45: ...TH L32E30R 45 11 2 16 A Board Sheet 100 1 3 1A 2A 3A ...
Страница 46: ...TH L32E30R 46 11 2 17 A Board Sheet 100 2 3 1B 2B 1A 2A 3A ...
Страница 47: ...TH L32E30R 47 11 2 18 A Board Sheet 100 3 3 1B 2B ...
Страница 48: ...TH L32E30R 48 11 2 19 A Board Sheet 101 1 3 1A 2A 3A 4A ...
Страница 49: ...TH L32E30R 49 11 2 20 A Board Sheet 101 2 3 1B 2B 1A 2A 3A 4A ...
Страница 50: ...TH L32E30R 50 11 2 21 A Board Sheet 101 3 3 1B 2B ...
Страница 51: ...TH L32E30R 51 11 2 22 A Board Sheet 300 1 1 ...
Страница 52: ...TH L32E30R 52 11 2 23 A Board Sheet 301 1 2 1A 2A ...
Страница 53: ...TH L32E30R 53 11 2 24 A Board Sheet 301 2 2 1A 2A ...
Страница 54: ...TH L32E30R 54 11 2 25 A Board Sheet 302 1 1 ...
Страница 55: ...TH L32E30R 55 11 2 26 A Board Sheet 700 1 2 1A 2A 3A ...
Страница 56: ...TH L32E30R 56 11 2 27 A Board Sheet 700 2 2 1A 2A 3A ...
Страница 57: ...TH L32E30R 57 11 2 28 A Board Sheet 701 1 2 1A 2A 3A ...
Страница 58: ...TH L32E30R 58 11 2 29 A Board Sheet 701 2 2 1A 2A 3A ...
Страница 59: ...TH L32E30R 59 11 2 30 A Board Sheet 702 1 1 ...
Страница 60: ...TH L32E30R 60 11 2 31 A Board Sheet 703 1 1 ...
Страница 61: ...TH L32E30R 61 11 2 32 A Board Sheet 704 1 1 ...
Страница 62: ...TH L32E30R 62 11 2 33 A Board Sheet 708 1 1 ...
Страница 63: ...TH L32E30R 63 11 3 KA Board 11 3 1 KA Board 1 2 1A 2A ...
Страница 64: ...TH L32E30R 64 11 3 2 KA Board 2 2 1A 2A ...
Страница 65: ...TH L32E30R 65 11 4 LD Board 11 4 1 LD Board 1 2 1A 2A 3A ...
Страница 66: ...TH L32E30R 66 11 4 2 LD Board 2 2 1A 2A 3A ...
Страница 67: ...TH L32E30R 67 11 5 P Board 11 5 1 P Board 1 3 1A 2A 3A ...
Страница 68: ...TH L32E30R 68 11 5 2 P Board 2 3 1B 2B 1A 2A 3A ...
Страница 69: ...TH L32E30R 69 11 5 3 P Board 3 3 1B 2B ...
Страница 86: ...Model No TH L32E30R Parts Location ...
Страница 87: ...Model No TH L32E30R Packing Exploded View ...