10.2. HD white balance adjustment
Instrument Name
Connection
Remarks
·
HD W / B pattern (COMPONENT Output)
·
Color analyzer
(Minolta CA-100 or equivalent)
PC input
Panel surface
User setting: Normal
(Picture menu: Standard)
Procedure
Remarks
·
Ensure aging is adequate.
·
Make sure the front panel to be used on the final set is fitted.
·
Make sure a color signal is not being shown before adjustment.
·
Put the color analyzer where there is little color variation.
1.
Set COMPONENT / RGB-IN SELECT to COMPONENT
2.
Select the IIC mode "PANEL W / B Adj.” item.
3.
Check that the color temperature is “COOL (High)”.
4.
Output a white balance pattern.
5.
Touch the signal receiver of color analyzer to the highlight window’s center.
6.
Fix G drive at E0h and adjust B drive and R drive so x, y become the "Color temperature
High" in the below table.
7.
Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
8.
Set color temperature to “NORMAL (Medium)”.
9.
Fix G drive at E0h and adjust B drive and R drive so the highlight window´s x, y becomes
the "Color temperature Medium" in the below table.
10. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
11. Set color temperature to "WARM (Low)".
12. Set G drive to E0h and adjust B drive and R drive so the highlight window´s x, y become
the “Color temperature Low” shown in the below table.
13. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
14. Copy the R drive, G drive and B drive data in YUV1_525ip, YUV3_625ip region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture Menu: Standard
Picture: 25
Aspect: Full
Position and size: Normal
·
Highlight section Signal amplitude 75%
·
Cutoff standard G: 80h
·
Drive standard G: E0h
35
TH-65PF9UK
Содержание TH-65PF9UK
Страница 4: ...1 Applicable signals 4 TH 65PF9UK ...
Страница 23: ...7 Location of Lead Wiring 23 TH 65PF9UK ...
Страница 24: ...24 TH 65PF9UK ...
Страница 27: ...8 4 Adjustment Volume Location 8 5 Test Point Location 27 TH 65PF9UK ...
Страница 32: ...9 2 IIC mode structure following items value is sample data 32 TH 65PF9UK ...
Страница 34: ...34 TH 65PF9UK ...
Страница 36: ...36 TH 65PF9UK ...
Страница 42: ...12 Option Setting 42 TH 65PF9UK ...
Страница 44: ...NOTE 44 TH 65PF9UK ...
Страница 78: ...NOTE TH 65PF9UK 78 ...
Страница 79: ...14 1 Schematic Diagram Notes 14 Block and Schematic Diagram TH 65PF9UK 79 ...
Страница 148: ...NOTE TH 65PF9UK 148 ...
Страница 149: ...15 Parts Location 15 1 Exploded View 15 1 1 The main mechanical parts relation 149 TH 65PF9UK ...
Страница 150: ...15 1 2 Escutcheon part location enlarged view 15 1 3 Fan part location enlarged view 150 TH 65PF9UK ...
Страница 151: ...15 2 Cable relation 151 TH 65PF9UK ...
Страница 152: ...15 3 Packing summary 152 TH 65PF9UK ...
Страница 154: ...17 Replacement Parts List 17 1 Replacement Parts List Notes 154 TH 65PF9UK ...