11
TH-58PF12UK
GPF12D chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful
for special function required customers. This should be set at the installation stage.
Note:
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R” button on the remote control and hold for more than 5 seconds.
The “SHIPPING“ menu is displayed and the lock is released when it disappears.
Option Menu for GPF12D series
Option menus
default setting
Contents
Weekly Command Timer
---
Sets Weekly Command Timer.
Onscreen display
On
Enable/Disable to display input mode indication after power on and no signal
indication.
Initial INPUT
Off
Sets the initial input mode when the power is turned on. Allow input mode selec-
tion while power is on.
Initial VOL level
Off
Sets the initial volume level when the power is turned on. Allow Volume control
while power is on.
Maximum VOL Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input
mode by input selection key.
Button lock
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume up/
down)
Remocon User Level
Off
Remote key invalidation.
Off: Valid key is all key of remote.
User1: Valid key are only Stand-by (ON/OFF), Input, Direct input, Picture, Sur-
round, Sound mute On/Off, and volume adjustment.
User2: Valid key is only Stand-by (ON/OFF).
User3: All keys are null and void
Off-timer function
Enable
Off-timer operation Enable/Disable.
Initial Power Mode
Normal
Sets the power mode of the unit for when the power recovers from failure or
after plugging off and in again.
ID select
0
Set ID number from 0 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
Off
Serial ID function On/Off
Display size
Off
Display size function On/Off
Studio W/B
Off
Studio W/B function On/Off
Studio Gain
Off
Studio Gain function On/Off
Slot power
Off
Sets the slot power mode while the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
Power On Screen Delay
Off
You can set the power-on delay time of the displays to reduce the power load,
when you press
to turn on the multiple displays that are set together, for
example, on MULTI DISPLAY system.
Set each display’s setting individually.
Clock Display
Off
Clock Display function On/Off.
All Aspect
Default
Aspect mode: default/All aspect mode.
Auto Setup
Manual
Sets the operational mode of the automatic position adjustment in the POS./
SIZE memu.
Rotate
Off
Rotate function On/Off
Serial Slot Select
Slot2
Selects the slot which communicates serial.
Note:
The setting of an external command can be set only from the fixed serial
terminal.
Содержание TH-58PF12UK
Страница 7: ...7 TH 58PF12UK 3 2 Applicable signals ...
Страница 8: ...8 TH 58PF12UK ...
Страница 10: ...10 TH 58PF12UK 5 Operating Instructions ...
Страница 15: ...15 TH 58PF12UK 6 2 IIC mode structure following items value is sample data ...
Страница 35: ...35 TH 58PF12UK 10 1 4 Adjustment Volume Location 10 1 5 Test Point Location ...
Страница 37: ...37 TH 58PF12UK ...
Страница 39: ...39 TH 58PF12UK ...
Страница 40: ...40 TH 58PF12UK ...
Страница 48: ...TH 58PF12UK 48 ...
Страница 49: ...49 TH 58PF12UK 12 Wiring Connection Diagram 12 1 Wiring ...
Страница 50: ...50 TH 58PF12UK ...
Страница 51: ...TH 58PF12UK 51 13 Schematic Diagram 13 1 Schematic Diagram Notes ...
Страница 95: ...TH 58PF12UK 95 A B C D E F G H I 1 2 3 4 5 6 P MULTI BOARD COMPONENT SIDE ETX2MM774MA ...
Страница 116: ...TH 58PF12UK 116 ...
Страница 162: ...Model No TH 58PF12UK Important Safety Notice ...
Страница 163: ...Model No TH 58PF12UK Exploded View ...
Страница 164: ...Model No TH 58PF12UK Cabinet part location ...
Страница 165: ...Model No TH 58PF12UK Fan part location ...
Страница 166: ...Model No TH 58PF12UK Flat cable ...
Страница 167: ...Model No TH 58PF12UK Packing and Accessories ...