TH-50VX100U / TH-50VX100E
9.2.
Adjustment
9.2.1.
RGB white balance adjustment
Instrument Name
Connection
Remarks
• RGB VGA60 W / B pattern
• Color analyzer
(Minolta CA-100 or equivalent)
PC input
Panel surface
User setting: Normal
(Picture menu: STANDARD)
Procedure
Remarks
[Condition]
• Ensure aging is adequate.
• Make sure the front panel to be used on the final set is fitted.
• Make sure a color signal is not being shown before adjustment.
• Put the color analyzer where there is little color variation.
[Adjustment]
1. Set COMPONET / RGB-IN SELECT to RGB.
2. Select the IIC mode “PANEL W / B Adj.” item.
3. Check that the color temperature is “COOL (Hi)”.
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at E0h and adjust B drive and R drive so x, y become the “Color temperature
COOL (Hi)” in the below table.
7. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
8. Set color temperature to “NORMAL (Mid)”.
9. Fix G drive at E0h and adjust B drive and R drive so the highlight window’s x, y becomes
the “Color temperature NORMAL (Mid)” in the below table.
10. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
11. Set color temperature to “WARM (Low)”.
12. Set G drive to E0h and adjust B drive and R drive so the highlight window’s x, y become
the “Color temperature WARM (Low)” shown in the below table.
13. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
14. Copy the R drive, G drive and B drive data in NTSC, PAL DVI region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture Menu: Standard
Aspect: Full
Position and size: Normal
• “7” key : color temperature select.
• “9” key : Picture menu select.
• Highlight section Signal amplitude 75%
• Drive standard G: E0h
Содержание TH-50VX100E
Страница 7: ...7 TH 50VX100U TH 50VX100E 3 2 Applicable signals ...
Страница 8: ...8 TH 50VX100U TH 50VX100E ...
Страница 10: ...10 TH 50VX100U TH 50VX100E 5 Operating Instructions ...
Страница 15: ...15 TH 50VX100U TH 50VX100E 6 2 IIC mode structure following items value is sample data ...
Страница 33: ...33 TH 50VX100U TH 50VX100E 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Страница 35: ...35 TH 50VX100U TH 50VX100E ...
Страница 37: ...37 TH 50VX100U TH 50VX100E ...
Страница 38: ...38 TH 50VX100U TH 50VX100E ...
Страница 47: ...47 TH 50VX100U TH 50VX100E 11 Wiring Connection Diagram 11 1 Wiring 1 ...
Страница 48: ...48 TH 50VX100U TH 50VX100E 11 2 Wiring 2 ...
Страница 49: ...49 TH 50VX100U TH 50VX100E 11 3 Wiring 3 ...
Страница 50: ...50 TH 50VX100U TH 50VX100E ...
Страница 51: ...TH 50VX100U TH 50VX100E 51 12 Schematic Diagram 12 1 Schematic Diagram Notes ...
Страница 52: ...TH 50VX100U TH 50VX100E 52 12 2 P Board 1 of 2 Schematic Diagram 0 1 0234 5 6 7 8 8 8 8 57 57 57 ...
Страница 169: ...Model No TH 50VX100U E Exploded View ...
Страница 170: ...Model No TH 50VX100U E Cabinet part location ...
Страница 171: ...Model No TH 50VX100U E Fan part location ...
Страница 172: ...Model No TH 50VX100U E Flat cable ...
Страница 173: ...Model No TH 50VX100U E Accessories ...
Страница 174: ...Model No TH 50VX100U E Packing 1 ...
Страница 175: ...Model No TH 50VX100U E Packing 2 ...