Option Menu for GPH8D series
GPH8D chassis series have special function and operation setting facility called Option Menu. This Option Menu is useful for
special function required customers. This should be set at the installation stage.
Option menus
default setting
Contents
Off-timer function
Enable
Off-timer operation Enable/Disable.
Onscreen display
On
Enable/Disable to display input mode indication after power on and no signal
indication.
Initial INPUT
Off
Sets the initial input mode when the power is turned on . Allow input mode
selection while power is on.
Initial VOL level
Off
Sets the initial volume level when the power is turned on. Allow Volume
control while power is on.
Maximum VOL Level
Off
Sets the maximum volume to desired level. Volume cannot exceed this level.
INPUT lock
Off
Fixes the input mode to AV, Component/RGB or PC. Can not change input
mode by input selection key.
Studio W/B
Off
Set warm mode color temperature to 3,200 Kelvin.
Advanced PIP
Off
Off : Sets normal two screen display mode.
On : Sets Advanced PIP mode.
Display size
Off
Adjusts the image display size on screen.
On : Sets the image display size approximately 95% of the normal image
display.
Button lock
Off
Enable/Disable bottom operation buttons (Input, Menu, Enter and/or volume
up/down)
Remocon User Level
Off
Remote key invalidation.
Off : Valid key is all key of remote.
User1 : Valid key are only Stand-by (ON/OFF), Input, Direct input, Status,
Surround, Sound mute On/Off, and volume adjustment.
User2 : Valid key is only Stand-by (ON/OFF).
User3 : All keys are null and void
ID select
0
Set ID number from 0 to 100.
Remote ID
Off
Remote ID function On/Off.
(While the Remote ID on, standard remote function can not control the unit.)
Serial ID
Off
Serial ID function On/Off
Slot power
Off
Sets the slot power mode while the power is turned on.
Allow Optional Terminal Board insert Slots while power is on.
V. Installation
Off
V. Installation function On/Off
This mode is available for TH-50PHD8UK.
Note:
Turn up the power switch for the upward direction when you set display
vertically.
Rotate
Off
The image rotates 180 degrees (up-down)
Note :
When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “RemoteID”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the “Volume down” button on main unit together with “R“ button on the remote control and hold for more than 5 seconds.
The “SHIPPING” menu is displayed and the lock is released when it disappears.
37
TH-50PHD8UK
Содержание TH-50PHD8UK - 50" Plasma Panel
Страница 4: ...1 Applicable signals 4 TH 50PHD8UK ...
Страница 21: ...8 Location of Lead Wiring 21 TH 50PHD8UK ...
Страница 22: ...22 TH 50PHD8UK ...
Страница 25: ...9 4 Adjustment Volume Location 9 5 Test Point Location 25 TH 50PHD8UK ...
Страница 28: ...10 2 IIC mode structure following items value is sample data 28 TH 50PHD8UK ...
Страница 36: ...13 Option Setting 36 TH 50PHD8UK ...
Страница 38: ...38 TH 50PHD8UK ...
Страница 64: ...TH 50PHD8UK 64 ...
Страница 65: ...15 Schematic Diagrams 15 1 Schematic Diagram Notes TH 50PHD8UK 65 ...
Страница 123: ...16 Parts Location 16 1 Exploded View 16 1 1 The main mechanical parts relation 123 TH 50PHD8UK ...
Страница 125: ...16 2 Cable relation 125 TH 50PHD8UK ...
Страница 126: ...16 3 Packing summary 126 TH 50PHD8UK ...
Страница 127: ...127 TH 50PHD8UK ...
Страница 129: ...18 Replacement Parts List 18 1 Relpacement Parts List Notes 129 TH 50PHD8UK ...