3.2. Initialization Pulse Adjust
1. Input the White signal to plasma video input.
2. Set the picture controls as follows.
·
Picture menu: Standard
·
Color temperature : Middle
·
Picture : 25
3. Connect Oscilloscope to TPSC1 (T1) and check for 15±10µ Sec.
4. Connect Oscilloscope to TPSC1 (T2) and adjust R6557 for 184+5µ /-10µ Sec.
Test point
Volume
Level
T1
TPSC1 (SC)
---
15 ± 10µ Sec
T2
TPSC1 (SC)
R6557 (SC)
184 + 5µ / - 10µ Sec