32
TH-42PH11UK
9.2.
Adjustment
9.2.1.
RGB white balance adjustment
Instrument Name
Connection
Remarks
• RGB VGA W / B pattern
• Color analyzer
(Minolta CA-100 or equivalent)
PC input
Panel surface
User setting: Normal
(Picture menu: Standard)
Procedure
Remarks
[condition]
• Ensure aging is adequate.
• Make sure the front panel to be used on the final set is fitted.
• Make sure a color signal is not being shown before adjustment.
• Put the color analyzer where there is little color variation.
1. Set COMPONET / RGB-IN SELECT to RGB.
2. Select the IIC mode “PANEL W / B Adj.” item.
3. Check that the color temperature is “COOL (High)”.
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at E0h and adjust B drive and R drive so x, y become the “Color temperature
High” in the below table.
7. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
8. Set color temperature to “NORMAL (Medium)”.
9. Fix G drive at E0h and adjust B drive and R drive so the highlight window’s x, y becomes
the “Color temperature Medium” in the below table.
10. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
11. Set color temperature to “WARM (Low)”.
12. Set G drive to E0h and adjust B drive and R drive so the highlight window’s x, y become
the “Color temperature Low” shown in the below table.
13. Increase R / G / B together so the maximum drive value in R / G / B becomes FCh.
14. Copy the R drive, G drive and B drive data in NTSC, PAL DVI region.
Adjustment target
Hi-light: x ± 0.003 y ± 0.003
Hi-light is target of the number at drive adjustment in the hi-light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Picture Menu: Standard
Picture: 25
Aspect: Full
Position and size: Normal
• Highlight section Signal amplitude 75%
• Cutoff standard G: 80h
• Drive standard G: E0h
Содержание TH-42PH11UK - 42" Plasma Panel
Страница 7: ...7 TH 42PH11UK 3 2 Applicable signals ...
Страница 9: ...9 TH 42PH11UK 5 Operating Instructions ...
Страница 14: ...14 TH 42PH11UK 6 2 IIC mode structure following items value is sample data ...
Страница 31: ...31 TH 42PH11UK 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Страница 33: ...33 TH 42PH11UK ...
Страница 35: ...35 TH 42PH11UK ...
Страница 45: ...45 TH 42PH11UK 11 Wiring Connection Diagram 11 1 Wiring 1 ...
Страница 46: ...46 TH 42PH11UK 11 2 Wiring 2 ...
Страница 47: ...TH 42PH11UK 47 12 Schematic Diagram 12 1 Schematic Diagram Notes ...
Страница 112: ...TH 42PH11UK 112 ...
Страница 156: ...Model No TH 42PH11UK Important Safety Notice ...
Страница 157: ...Model No TH 42PH11UK Exploded View ...
Страница 158: ...Model No TH 42PH11UK Cabinet part location ...
Страница 159: ...Model No TH 42PH11UK Fan part location ...
Страница 160: ...Model No TH 42PH11UK Flat cable ...
Страница 161: ...Model No TH 42PH11UK Accessories ...