42
Options Adjustments
Item
Adjustments
Button lock
Off
On
MENU&ENTER
Off:
All the buttons on main unit can be used.
MENU&ENTER:
Locks
MENU
and
ENTER/
buttons on main unit.
On:
Locks all the button on main unit.
Sets Button lock with the unit buttons in the following procedure.
Off:
Press four times
→
Press
INPUT
four times
→
Press four times
→
Press
ENTER/
MENU&ENTER:
Press
ENTER/
four times
→
Press four times
→
Press
INPUT
four times
→
Press
ENTER/
On:
Press four times
→
Press
ENTER/
four times
→
Press four times
→
Press
ENTER/
Remocon User level
Off
User1
User2
User3
Off:
You can use all of the buttons on the remote control.
User1
: You can only use
, , , ,
buttons on the remote control.
User2
: You can only use
button on the remote control.
User3:
Locks all the buttons on remote control.
Off-timer function
Enable:
Enables the “Off-timer function”.
Disable:
Disables the “Off-timer function”.
Note:
When “Disable” is set, the Off-timer is cancelled.
Initial Power Mode
Normal
On
Standby
Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again.
Normal:
Power returns in as the same state as before the power interruption.
Standby:
Power returns in standby mode. (Power Indicator : red/orange)
On:
Power returns in power On. (Power Indicator : green)
Note:
When using multiple displays, “Standby” is preferred to be set in order to reduce a power load.
Power On Screen
Delay
Off
1
2
3....
30
You can set the power-on delay time of the displays to reduce the power load, when you press
to
turn on the multiple displays that are set together, for example, on MULTI DISPLAY system.
Set each display’s setting individually.
Off:
The display will be turned on at the same time as
is pressed.
1 to 30 (sec.):
Set the power-on delay time (second).
After pressing
, the display will be powered on with time delay depending on this setting.
Notes:
• During this function is working, the power indicator is blinking green.
• This function also works when the power recovers from failure or after plugging off and in again the
power cord.
Clock Display
Off:
Not display the clock.
On:
Display the clock.
The clock is displayed at the lower left of the screen when button is pressed.
Note:
When “PRESENT TIME Setup” is not set, the clock is not displayed even
if “Clock Display” is “On”. (see page 27)
10:00
Normalization
When both main unit buttons and remote control are disabled due to the “Button lock” or “Remocon User level”
adjustments, set all the values “Off” so that all the buttons are enabled again.
Press the button on main unit together with
button on the remote control and hold for more than 5 seconds. The
“Shipping” menu is displayed and the lock is released when it disappears.
Содержание TH-42LF20W
Страница 47: ...47 Memo ...