TH-40A400X
3
1 Safety Precautions
1.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
5. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
6. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When the
exposed metallic part has a return path to the chassis, the
reading should be 8.5Mohm to 13Mohm.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
1.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should
be repaired and rechecked before it is returned to the
customer.
Figure 1
Содержание TH-40A400X
Страница 25: ...TH 40A400X 25 10 Schematic Diagram Model No TH 40A400X A Board 1 12 ...
Страница 26: ...Model No TH 40A400X A Board 2 12 ...
Страница 27: ...Model No TH 40A400X A Board 3 12 ...
Страница 28: ...Model No TH 40A400X A Board 4 12 ...
Страница 29: ...Model No TH 40A400X A Board 5 12 ...
Страница 30: ...Model No TH 40A400X A Board 6 12 ...
Страница 31: ...Model No TH 40A400X A Board 7 12 ...
Страница 32: ...Model No TH 40A400X A Board 8 12 ...
Страница 33: ...Model No TH 40A400X A Board 9 12 ...
Страница 34: ...Model No TH 40A400X A Board 10 12 ...
Страница 35: ...Model No TH 40A400X A Board 11 12 ...
Страница 36: ...Model No TH 40A400X A Board 12 12 ...
Страница 37: ...Model No TH 40A400X K Board ...
Страница 38: ...Model No TH 40A400X P Board ...
Страница 39: ...39 11 Printed Circuit Board Model No TH 40A400X A Board Top Component Side TH 40A400X ...
Страница 40: ...Model No TH 40A400X A Board Bottom Component Side ...
Страница 41: ...Model No TH 40A400X K Board ...
Страница 42: ...Model No TH 40A400X P Board Top Component Side ...
Страница 43: ...Model No TH 40A400X P Board Bottom Component Side ...
Страница 44: ...TH 40A400X 44 12 Exploded View and Replacement Parts List Model No TH 40A400X Parts Location ...
Страница 45: ...Model No TH 40A400X Packing Exploded View 1 ...
Страница 46: ...Model No TH 40A400X Packing Exploded View 2 ...