16
7.2.12. Remove the Cabinet assy from the
Plasma panel section.
1. Place the Cabinet assy on a flat surface of a table
(covered by a soft cloth) and a cushion.
2. Remove the screws (x2
, x3
).
3. Remove the Cabinet assy from the Plasma panel section.
7.2.13. Remove the Contact metal bottom
1. Remove the screws (
8
) and remove the Contact
metal bottom.
7.2.14. Remove the C1-Board
1. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).
2. Disconnect the flexible cable (C10).
3. Remove the screws (
4
) and remove the C1-Board.
7.2.15. Remove the C2-Board
1. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).
2. Disconnect the flexible cables (C20 and C21).
3. Disconnect the connector (C25).
4. Remove the screws (
4
) and remove the C2-Board.
7.2.16. Replace the Plasma panel
Caution:
Place the Plasma panel on a flat surface of a table
(covered by a soft cloth) and a cushion.
A new Plasma panel itself without Contact metals is fragile.
To avoid the damage to new Plasma panel, carry a new
Plasma panel taking hold of the Contact metal bottom.
1. Place a carton box packed a new Plasma panel on the
flat surface of the work bench.
2. Open a box and without taking a new Plasma panel.
3. Attach the Cabinet assy and each P.C.Board and so on,
to the new Plasma panel.