Slide # 34
Inverter Circuit and 1 Blink SOS
The INV_ON/OFF command (high) of the MPU, IC8001 of the A board,
enters the P-Board to turn on the inverter circuit. The inverter circuit
produces AC voltages that power the backlight fluorescent lamps . The
output of the inverter, approximately 2Kvp-p is provided to the LCD panel
via the connectors P5, P6, P7 and P8.
To avoid catastrophic failures, when the inverter circuit is defective, the
INV_SOS command is output to IC8001 to trigger the shutdown of the TV.
The power LED blinks one time. The same operation takes place when
there is an impedance mismatch between the Panel and the inverter.
IC7800 is the controller. IC7801 is the oscillator that provides the switching
signals to the transistors Q7801 through Q7804.
The backlights are manipulated (dimmed) by the control signal INV_PWM
coming from the main board Via pin 12 of the connector P2.
Содержание TC-L32C22 Quick Setup Guide (English
Страница 25: ...Slide 25 Power on Part 1_ All Except D2 ...
Страница 27: ...Slide 27 Power On Part 2_ All Series Except D2 ...
Страница 29: ...Slide 29 Power on Part 1_ D2 Series The difference in this drawing is the pin numbers of connector A03 ...
Страница 30: ...Slide 30 Power On Part 2_ D2 series ...
Страница 33: ...Slide 33 TC L32U22 Inverter Circuit and 1 Blink SOS ...
Страница 35: ...Slide 35 LED Backlight Control ...
Страница 47: ...Slide 47 SOS Detect Shutdown ...
Страница 50: ...Slide 50 TC L32U22_1 Blink SOS Circuit ...
Страница 53: ...Slide 53 3 and 7 Blinks SOS Circuit ...
Страница 80: ...Slide 80 Troubleshooting Picture problem D Series Troubleshooting Picture problem D Series ...