DIALPLAN_MEMORY_DIAL_ENABLE
Value Format
BOOLEAN
Description
Specifies whether to enable Dial Plan processing for memory dialing.
Value Range
•
Y
: Enable Dial Plan
•
N
: Disable
Default Value
Y
MACRODIGIT_TIM
Value Format
INTEGER
Description
Specifies the length of time, in seconds, that the unit waits when a "T"
or "t" has been entered in the dial plan.
Value Range
1–15
Default Value
5
Web User Interface Reference
INTERNATIONAL_ACCESS_CODE
Value Format
STRING
Description
Specifies the number to be shown in the place of the first "+" symbol
when the phone number for incoming international calls contains "+".
Value Range
Max. 8 characters (consisting of 0–9, *, and #)
Note
•
No other characters are allowed.
Default Value
Empty string
Web User Interface Reference
COUNTRY_CALLING_CODE
Value Format
STRING
Description
Specifies the country/area calling code to be used for comparative
purposes when dialing a number from the incoming call log that
contains a "+" symbol.
Value Range
Max. 8 characters (consisting of 0–9)
Default Value
Empty string
Web User Interface Reference
NATIONAL_ACCESS_CODE
Value Format
STRING
Description
When dialing a number from the incoming call log that contains a "+"
symbol and the country calling code matches, the country calling
code is removed and the national access code is added.
Value Range
Max. 8 characters (consisting of 0–9, *, and #)
5.3.34 Call Control Settings