background image

Page 8 of  10

Model
Name

Model
No.

Switch-M2

PN28248-SG

Product Specification

401-28248-SG-SP01

Date issued

Date revised

July 4, 2016

Panasonic Eco Solutions Networks Co., Ltd.

10. Installation Procedures and Accessories

10-1.Installation Procedures

Mounting to rack

(1) Installation Guide

:1

(2) CD-ROM

:1

(3) Rubber foot

:4

(4) Mounting bracket (for 19-inch rack)

:2

(5) Screw(for 19-inch rack)

:4

(6) Screw (for fixing the main unit and the 19 inch rack mount bracket)

:8

(7) Power cord (BS1363)(*)

:1

* The attached power cord is dedicated for AC 100 - 240 V use.

10-2.Accessories

11. Optional Accessories

Fiber optic port connector type :LC connector (Duplex)

Standards

:IEEE802.3z

1000BASE-SX

Transmission speed                         :1000Mbps, full duplex
Compatible cable

:Fiber cable

50/125μm Multi Mode Fiber
62.5/125μm Multi Mode Fiber

Maximum transmission distance

:550 m at 50/125 μm

220 m at 62.5/125 μm

11-1. 1000BASE-SX

SFP Module

(Model No. :PN54021K-SG)

11-2. 1000BASE-LX

SFP Module

(Model No.:PN54023K-SG)

Fiber optic port connector type :LC connector (Duplex)

Standards

:IEEE802.3z

1000BASE-LX

Transmission speed                         :1000Mbps, full duplex
Compatible cable

:Fiber cable

10/125μm   Single Mode Fiber
50/125μm  Multi Mode Fiber
62.5/125μm  Multi Mode Fiber

Maximum transmission distance

:10 km when Single Mode Fiber is used

550 m when Multi Mode Fiber is used

9-1. Port 1 - 26

9-2. Console port

Status

MDI-X

MDI

Pin No.

Signal

Signal

1

2

3

6

4

5

8

7

BI_DB+

BI_DA+

BI_DB-

BI_DA-

BI_DA+

BI_DB+

BI_DA- BI_DD+

BI_DB- BI_DC+

BI_DD-

BI_DC-

BI_DC+

BI_DD+

BI_DC-

BI_DD-

Pin No. 

1
2
3
4

NC
NC

TXD

GND

5
6
7
8

GND

RXD

NC
NC

Pin No.

1 2 3 4 5 6 7 8

Pin No.

1 2 3 4 5 6 7 8

Signal

Pin No. 

Signal

9. Connector Pin Arrangement

Содержание Switch-M24eGLPWR+ Series

Страница 1: ...n Ports 1 to 16 are set at MDI X default 5 Telnet allows remote configuration changes and verifications of the Switching Hub Remotely configure the PoE settings for each port Ports 1 to 24 6 Equipped with energy efficient Ethernet EEE conforming to IEEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on ...

Страница 2: ...nergy saving state automatically starts so that power consumption can be reduced on each port SFP extension slot 25 26 SFF 8472 DMI Diagnostic Monitoring Interface Select either of RJ45 or SFP for use Optional Accessories 1000BASE SX SFP Module PN54021K SG 1000BASE LX SFP Module PN54023K SG 3 Rated Environmental Conditions 5 Hardware Specifications 4 1 Form and materials colors 4 2 Mass Weight 3 9...

Страница 3: ...he Switching Hub is exceeding 185 W 4 FAN LED Fan sensor Green Light System is operating normally Orange Blink Fan fault is occurring 5 TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 67 factory default 6 LOOP HISTORY LED Loop History ...

Страница 4: ...l connected via TELNET and SSH 3 Configuration from a remote terminal via the Internet Management protocol SNMP v1 v2c RFC1157 RFC1901 TELNET RFC854 SSH v2 RFC4251 RFC4252 RFC4253 RFC4254 RFC4716 Data transfer protocol TFTP RFC783 Switching Hub can be controlled by the following procedures 1 Control from an asynchronous terminal connected to the console port 2 Control from a remote terminal using ...

Страница 5: ...loop has occurred within the latest 3 days LOOP HISTORY LED blinks to notify this Loop detection setting Enabled factory default setting Enabled disabled can be switched by configuring a setting using the console The setting is kept even when the power is turned OFF Loop detection port Enabled Ports 1 to 24 factory default setting Disabled Ports 25 and 26 factory default setting Loop shutoff time ...

Страница 6: ...nction 7 6 QoS IEEE802 1p Four levels of Priority Queue supported Scheduling Method Priority Queuing PQ Strict priority queuing Weighted Round Robin WRR Weighted round robin scheduling DSCP Mapping function 7 7 Authentication Function IEEE802 1X Port based authentication EAP Packet Forwarding function Enable disable EAP transmission can be specified for each port 7 8 PoE power supply function IEEE...

Страница 7: ...ion System Security Configuration ID Password Change Forwarding Database FDB Configuration Time SNTP Configuration VLAN Configuration Link Aggregation Configuration Port Monitoring Configuration QoS Configuration Storm Control Configuration Static ARP Table LLDP Configuration 802 1X Access Control Configuration Spanning Tree Configuration Loop Detection Configuration DDM Configuration RRP Domain M...

Страница 8: ...le cable Fiber cable 50 125μm Multi Mode Fiber 62 5 125μm Multi Mode Fiber Maximum transmission distance 550 m at 50 125 μm 220 m at 62 5 125 μm 11 1 1000BASE SX SFP Module Model No PN54021K SG 11 2 1000BASE LX SFP Module Model No PN54023K SG Fiber optic port connector type LC connector Duplex Standards IEEE802 3z 1000BASE LX Transmission speed 1000Mbps full duplex Compatible cable Fiber cable 10 ...

Страница 9: ...ead to electrical shock and or equipment failure 7 Do not insert nor drop any foreign objects such as metal or readily combustible things into the inside through the openings Deviation could lead to fire electrical shock and or equipment failure 8 Do not store or use the Switching Hub in places where it might get splashed with liquids such as water in places with a lot of humidity in places with c...

Страница 10: ... periodically serviced in order to maintain its performance Please choose a product administrator and have them be sure to implement periodic maintenance When doing maintenance check the inspection chart that is posted on our website which has the requisite items listed on it 12 When using this Switching Hub to design systems use it after applying appropriate measures such as setting up redundant ...

Отзывы: