background image

1. Basic operation

 

● When  a  hand  is  touched  to  the  sensing  surface,  thru-beam 

type photoelectric sensor detects the hand, and output turns 

ON or OFF.

FUNCTIONS

5

2. Output

 

● Three semiconductor photo MOS relays are incorporated.

Output 1  : When an object is detected (beam is interrupted)

OFF 

/

 

  When an object is not detected (beam is received)

ON

Output 2, 3 : When an object is detected (beam is interrupted)): ON / 

 

  When an object is not detected (beam is received)

OFF

Note: When the power of the thru-beam type photoelectric sensor inside the main body turns 

ON in beam interrupted condition, output 1 turns ON, while outputs 2 and 3 turn OFF, 

then the fault indicator (yellow) lights up.  In this case, once beam is received, the fault 

indicator turns OFF and the sensor returns to normal operation.  

3. Time-out function

 

● Unintended beam interrupted condition caused by dirt on the sensing surface, 

etc. can be monitored. 

•  When beam interrupted condition (sensing condition) continues for 10 sec. 

or more, output 1 turns ON, while output 2 and 3 turn OFF (output condition 

is the same as non-sensing condition.)

•  This function can be invalid by short-circuiting “between switching terminals 

of time-out function  (terminal No. 7 and No. 8)” as described below.

Note:  When time-out function is operated, the fault indicator (yellow) lights up. In this case, 

once beam is received, the fault indicator turns OFF and the sensor returns to normal 

operation. 

Short-circuit between the switching 

terminals of time-out function 

7 8

4. External input function

 

● External input indicators 1 and 2 of this product light up by the signal from 

external input.

External input indicators 1 and 2:

Lights up when external input indicators 1 and 2 are valid (0 to 1V or 10V to +V).

Turns OFF when external input indicators 1 and 2 are invalid (4 to 6V or open).

Sensing

condition

10 sec. 

or more

Sensing

Non-

sensing

Turns OFF

Lights up

OFF

ON

OFF

ON

OFF

ON

Fault

indicator

Output 1

Output 2

Output 3

<Timing Chart (In case time-out function works)>

Connecting to the terminal block

 

● When connecting to the terminal block, push the cable 

with ferrule terminal into the back of the mounting hole. 

If the cable is properly inserted, the lock is completed 

and the cable does not fall if it is pulled.  

 

● In case of using twisted wire directly, hold down the 

release button and plug the cable into the back as 

shown in the right figure. Conforming cable diameter 

is shown below.

 

● In case of removing, hold down the release button and 

pull the cable.  

Cable with no ferrule terminal (Twisted wire)

Cable with ferrule terminal

0.2 to 1.5mm

(AWG 24 to 16)

0.2 to 1.5mm

2

<Conforming cable>

Release

button 

Terminal layout

A side terminal block

B side terminal block

<Bottom view>

1 2 3 4 5 6

7 8 9 10 11 12

 

● As the shape is different between A side terminal (termi

-

nal No. 1 to 6) and B side terminal (terminal No. 7 to 12), 

make sure to wire properly.

Terminal No. Terminal name

Description

1

12 to 24V DC

+V

2

Output 1

Output 1_1

3

Output 1_2

4

Output 2

Output 2_1

5

Output 2_2

6

0V

0V

Terminal No.1 has

no projection

<A side terminal block>

Terminal No. Terminal name

Description

7

Timer (+V)

Switching terminal of time-

out function (+V)

8

Timer (IN)

Switching terminal of time-

out function (IN)

9

Output 3

Output 3_1

10

Output 3_2

11

IN2 (Orange) External input 2

12

IN1 (Green)

External input 1

<B side terminal block>

Terminal No.12 has 

no projection

Designation

Optical touch switch

Item

Model No.

SW-101

Applicable standard

CSA 22.2 No.14, CSA 22.2 No.0.8, ANSI/NFPA 79, UL 508, 

EN 60947-5-2 (EMC only)

Sensing method

Thru-beam type photoelectric sensor (2 beam axes)

Supply voltage

12 to 24V DC±10%, Ripple P-P10% or less 

Current consumption

100mA or less (Excluding external connection load)

Output

Semiconductor photo MOS relay output × 3

• Maximum load current: 100mA

• Applied voltage: 30V DC or less (between output and +V)

• Residual voltage: 1.5V or less (at 100mA of load current)

Output operation

Output 1     : 

When an object is detected (light is blocked): OFF /

When an object is not detected (light is received): ON

Output 2, 3 : When an object is detected (light is blocked): ON /

When an object is not detected (light is received): OFF

Short-circuit protection

Incorporated

Response time

100ms or less when an object is detected

50ms or less when an object is not detected

Protection

IP65 (IEC) TYPE1 (UL 50) (Excluding terminal area)

Ambient temperature

-25 to +50°C (No dew condensation or icing allowed)

Storage: -30 to +70°C

Ambient humidity

30 to 85% RH, Storage: 30 to 85% RH

Material

Enclosure: Polycarbonate, Polyester resin 

Nut: PBT, Mouting packing: Silicone rubber

Connection cable 

length

Up to 20m (cable diameter: 0.2 to under 0.3mm

2

)

Up to 100m (cable diameter: 0.3 or more to 1.5mm

2

)

Weight

Approx. 130g

SPECIFICATIONS

7

 

● This product has been developed / produced for industrial use only. 

 

● Confirm the wiring before power is supplied, as wrong wiring will damage the 

internal circuit.

 

● Verify that the supply voltage variation is within the rating.

 

● If power is supplied from a commercial switching regulator, ensure that the frame 

ground (F.G.) terminal of the power supply is connected to an actual ground.

 

● Use a power supply unit conforming to the EMC Directive and the Low Voltage 

Directive. (Only for use in Europe)

 

● Use a power supply unit conforming to CLASS 2. (Only for use in the United States)

 

● Use a power supply unit with an output holding time of 20ms or more.

 

● Do not use during the initial transient time (approx. 300ms) after the power 

supply is switched ON.

 

● Make sure to use an isolation transformer for the DC power supply. If an auto-transformer 

(single winding transformer) is used, this product or the power supply may get damaged.

 

● In case a surge is generated in the used power supply, connect a surge ab

-

sorber to the source and absorb the surge.

 

● Make sure that the power is OFF while wiring.

 

● Do not run the wires together with high-voltage lines or power lines or put 

them in the same raceway. This can cause malfunction due to induction.

 

● In order to reduce noise, make the wiring as short as possible.

 

Do not use this product in places having excessive vapor, dust, etc.

 

● Take care that the product does not come in contact with oil, grease, or or

-

ganic solvents such as thinner, etc.

 

● Do not hit the product by a hammer etc. when mounting, as the product get damaged.

 

● This product is suitable for indoor use only.

CAUTIONS

8

TROUBLESHOOTING

6

 

● Fault indicator (yellow) blinks when an error occurs.

 

● An error can be identified by the number of blinks of the fault indicator.

Blinking 

number

Error

Status of sensor

Countermeasure

1

Output 

short-circuit

Lockout

Check the wiring of output.

2

Dirt error

Normal operation Wipe out the sensing surface with a soft cloth.

4

Extraneous 

light error

Lockout

Place the product so that extraneous light 

is not received at its sensing surface. 

5

Internal error

Lockout

Check that there is no noise around the 

product. Also check the environment for 

power supply and wiring.

In case the product does not operate normally 

after checking the above measures, contact 

Panasonic Industrial Devices SUNX Co., Ltd.

6

Emission 

circuit error

Lockout

7

Reception 

circuit error

Lockout

 

● In case of lockout condition, when upper countermeasure is performed and 

the power is supplied again, the operation returns to normal.

0.3s

0.3s

Turns OFF

Lights up

2s

<Blinking cycle of the fault indicator [(e.g.) The number of blinks: 2 times]>

 

 

The models listed under “

SPECIFICATIONS

” come with CE Marking.

As for all other models, please contact our office.

 

Contact for CE

Panasonic Marketing Europe GmbH Panasonic Testing Center

Winsbergring 15, 22525 Hamburg,Germany

INTENDED PRODUCTS FOR CE MARKING

9

http://panasonic.net/id/pidsx/global

Overseas Sales Division (Head Office) 

2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan 

Phone: +81-568-33-7861  FAX: +81-568-33-8591

For sales network, please visit our website.

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2016 

Ramco National

www.PanasonicSensors.com

1-800-280-6933

Отзывы: