10
6.5.
SERVICE 3
Battery Capacity Display and
Control Button Operation
Check
[ Content ]
Displays the rechargeable battery voltage, and the KEY IN volt-
age AD conversion values (hexadecimal) at the [FWD-Skip],
[REW-Skip], [MODE], [MARK], [+], [-] key operations.
The AD conversion value is used for button operation checks
and for the remaining battery capacity display.
[ Operating procedure ]
1. Select [ SERVICE 3 ] on the service mode menu and then
press the [PLAY/STOP] button, then displayed the battery
capacity display and control button operation check
screen.
2. Turn the power OFF to complete the procedure.
6.5.1.
BATT (Remaining Battery Capacity
AD Value)
Check the BATT's AD conversion value and the remaining
battery capacity display.
The BATT display (hexadecimal) indicates the voltage of the
internal rechargeable battery.
The internal rechargeable battery voltage =
2.9 (V) x [BATT display content] / 1024.
[Example]
When the BATT value is "1CC" ("460" as decimal value):
Internal rechargeable battery voltage = 2.9 x 460 / 1024 =
1.3027....= 1.303 (V)
The value of BATT2: is not used in this mode.
6.5.2.
KEYIN (Control Button’s AD Value)
Displays the AD value judgment for the button operation.
Press each of the [FWD-Skip], [REW-Skip], [MODE], [MARK],
[+], [-] buttons and verify the changes in the KEYIN's AD
conversion value.
Judgment:
If the AD conversion value displayed at the button operation
is outside the range shown in the table, this may indicate a
hardware malfunction.
Remaining Battery Voltage
Display
AD Conversion Value
3 battery marks
1C3 < Batt
2 battery marks
1B3 < Batt < or = 1C3
1 battery mark
19B < Batt < or = 1B3
Blinking battery mark
172 < Batt < or = 19B
Low battery voltage
Batt < or = 172
Button Operation
AD Conversion Value
FWD-Skip
000 ~ 055
REW-Skip
056 ~ 0FF
MARK
100 ~ 1AA
+
1AB ~ 255
-
256 ~ 2FF
MODE
300 ~ 3AA
No key input
3AB ~ 3FF
Содержание SV-SD350VGC