22
Specifications
*
Nominal output: Output of a single motor determined under a certain standard.
*
The power to be consumed by the entire product is indicated in the power consumption item.
Please refer to this value when using for your purpose.
*
Dimensions W×D×H indicate the width × depth × height.
1-phase 240 V 50 Hz
Commercial Freezer
SRF-K1281-ME
SRF-K1581-ME
1 200×800×1 950
1 100×700×1 450
1 460×800×1 950
1 360×700×1 450
1 081 L
128
NJ
147
NJ
1 343 L
1-phase 240 V 50 Hz
Type BF 2-pole plug with a grounding pole
2-pole receptacle with a grounding pole, 13 A, 250 V
6 wire shelves, 2 wire shelves (for bottom level), 24 shelf brackets,
1 operating instruction booklet, 1 set fall prevention bracket
Polyethylene coated wire
Ambient temperature 30
℃
No direct sunshine during no load equilibrium condition
-20
℃
or below
-25
℃
to -15
℃
Nominal output 400 W
R404A
DC12 V 2 W×2
DC12 V 8.4 W
452 W/2.91 A
549 W/2.35 A
300 W/2.70 A
553 W/2.10 A
3.0 m
Product name
Model No.
Exterior
(
W×D×H
)
(
mm
)
Interior
(
W×D×H
)
(
mm
)
Rated internal volume
Adjustable shelf
Condition
Compartment temperature
Compartment set
temperature range
Compressor
Refrigerant
For cooling unit
For condenser
Power source
Power
consumption
/Ratet Input
Current
During cooling
During defrosting
Length
Plug
Usable power receptacle
Fan
Power
code
Accessories
Net weight
Commercial Refrigerator
SRR-K1281-ME
SRR-K1581-ME
1 200×800×1 950
1 100×700×1 450
1 460×800×1 950
1 360×700×1 450
1 087 L
125
NJ
144
NJ
1 343 L
-6
℃
to 12
℃
R134a
DC12 V 8.4 W
215.3 W/1.63 A
458.9 W/1.92 A
DC12 V 4 W
161.9 W/1.10 A
339.6 W/1.42 A
3.0 m
Cooling unit
Electrical rating
Power source
Product name
Model No.
Exterior
(
W×D×H
)
(
mm
)
Interior
(
W×D×H
)
(
mm
)
Rated internal volume
Adjustable shelf
Condition
Compartment temperature
Compartment set
temperature range
Compressor
Refrigerant
For cooling unit
For condenser
Power source
Power
consumption
/Ratet Input
Current
During cooling
During defrosting
Length
Plug
Usable power receptacle
Fan
Power
code
Accessories
Net Weight
Ambient temperature 30
℃
No direct sunshine during no load equilibrium condition
Polyethylene coated wire
-5
℃
or below
Nominal output 170 W
DC12 V 4 W×2
Type BF 2-pole plug with a grounding pole
2-pole receptacle with a grounding pole, 13 A, 250 V
6 wire shelves, 2 wire shelves (for bottom level), 24 shelf brackets,
1 drain hose, 1 operating instruction booklet, 1 set fall prevention bracket
Size
Performance
Cooling unit
Electrical rating
Power source
Size
Performance