9 Measurements and Adjustments
9.1.
Adjustment Procedure
9.1.1.
Driver Set-up
9.1.1.1.
Item / Preparation
1. Input a white signal to plasma video input.
2. Set the picture controls as follows.
Picture menu : Dynamic
PNR : Min
Aspect : 16:9
Caution
1. First perform Vsus adjustment.
2. The Vscn voltages are measured from the Vad (Vad_base), but may be measured from the GND (GND_base) in an
unavoidable case.
9.1.1.2.
Adjustments
Adjust driver section voltages referring the panel data on the panel data label.
Check or adjust the following voltages with the multimeter.
*See the Panel label.
Name
Test Point
Voltage
Volume
Remarks
Vsus
TPVSUS (SS)
Vsus ± 2V
VR201 (P)
*
Ve
TPVE (SS)
Ve ± 2.5V
Fixed
*
Vset
TPVSET (SC)
290V ± 9V
Fixed
Vad
TPVAD (SC)
- 175V ± 2V
VR16600 (SC)
Vscn
TPVSCN (SC)
Vad_base : 145V ± 4V
GND_base : - 30V ± 6V
Fixed
Содержание SP-54Z1A
Страница 24: ...24 6 4 No Picture ...
Страница 41: ...41 9 1 4 Adjustment Volume Location 9 1 5 Test Point Location ...
Страница 42: ...42 ...
Страница 54: ...54 11 3 Wiring Display unit 1 11 4 Wiring Display unit 2 ...
Страница 55: ...55 11 5 Wiring Display unit 3 11 6 Wiring Display unit 4 ...
Страница 56: ...56 11 7 Wiring Display unit 5 11 8 Wiring Display unit 6 ...
Страница 57: ...57 12 Schematic Diagram 12 1 Schematic Diagram Note ...
Страница 146: ...146 ...
Страница 148: ...148 14 1 2 Exploded View 2 Display unit ...
Страница 149: ...149 14 1 3 Exploded View 3 Display unit ...
Страница 150: ...150 14 1 4 Packing 1 ...
Страница 151: ...151 14 1 5 Packing 2 ...
Страница 152: ...152 14 1 6 Packing 3 ...
Страница 153: ...153 14 1 7 Packing 4 Pedestal stand ...
Страница 154: ...154 14 1 8 Packing 5 ...
Страница 155: ...155 14 1 9 Packing 6 ...
Страница 156: ...156 14 1 10 Packing 7 ...
Страница 162: ...162 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...