PRECAUTIONS
7
Short-circuit protective function is not incorporated in the output. If the
output is short-circuited, product breakage or burnout may occur.
● This product has been developed / produced for industrial use only.
● Make sure to carry out wiring and relay replacement in the power supply
OFF condition.
● Make sure to check the wiring before the power supply is switched ON.
If the power supply is switched ON when the wiring is incorrect, there is
a danger of malfunction or damage.
● In case noise generating equipment (switching regulator, inverter mo-
tor, etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
● Do not run the wires together with high-voltage lines or power lines or
put them in the same raceway. This can cause malfunction due to in-
duction.
● A switch cap is attached to the setting switches area. In case of setting,
remove the switch cap. After setting, attach the switch cap to the setting
switches area.
● This product does not have a dust-proof or water-proof construction.
Do not use the product in places having excessive vapor, dust, etc., or
where it may come in contact with corrosive gas, etc.
● Take care that the product does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid, or alkaline.
● Make sure to fit the cover before use.
SPECIFICATIONS
6
Notes: 1) This product is incorporated with the PA-N relay manufactured by Panasonic Co.,
Ltd. However, when you replace the relay, you can also use the PhotoMOS relay
manufactured by Panasonic Co., Ltd.
For a detailed description, refer to “
RELAY REPLACEMENT
.”
2) If this unit is installed in a control box along with other units, the ambient
temperature may exceed the rated value due to the heat generated by the units.
In this case, make sure that the ambient temperature does not exceed the rated
value by installing a fan, etc.
3) This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Type
4-channel
8-channel
Item
Model No.
SL-VTPR4
SL-VTPR8
Supply voltage
24V DC±10% (Supplied from
S-LINK V
controller or separate power supply)
Current consumption
90mA or less
(When all points are ON)
150mA or less
(When all points are ON)
Address setting
Using switches, in the range of 0 to 511
Output
Relay contact 1a (Note 1)
• Nominal switching capacity: Under 50V, 3A AC (resister load)
However, if compatibility with the CE is not necessary, use
of 250V, 3A AC is possible.
30V, 3A DC (resister load)
• Min. switching capacity : 5V 1mA DC (Note 3)
• Electrical life: 100,000 times of operation or more
(rated load, switching frequency of 20 times/min)
• Mechanical life: 20,000,000 times of operation or more
(switching frequency of 180 times/min)
Output operation The output relay is turned ON if the output signal from the sig-
nal transmission line is turned ON.
Number of output points
4 points
8 points
Output holding function
Incorporated
Ambient temperature
(Note 2)
-10 to +55°C (No dew condensation or icing allowed)
Storage: -20 to +70°C
Ambient humidity
35 to 85% RH, Storage: 35 to 85% RH
Material
Enclosure: PC-ABS resin, Cover: Polycarbonate
DIN rail stopper: POM, Relay remover key: POM
Weight
Approx. 100g
Approx. 160g
Accessory
Cover: 1 pc., Switch cap: 1 pc., Relay remover key: 1 pc.
CONNECTION
4
●
Connection to 4-core flat cable
• If the exclusive flat cable has been used for
the main / branch cable on the
S-LINK V
system, use the optional exclusive hook-up
connectors to connect the 4-core flat cable
of the product to the main / branch cable by
matching the wire colors.
Main / branch cable
Exclusive hook-up
connector
4-core flat cable
Match the
wire colors
●
Wiring on a terminal block
• Use crimp terminals having dimensions given in the table below for wir-
ing on a terminal block.
Dimensions of suitable crimp terminals
Y type
Round type
Dimensions
(Unit: mm)
5.6
or less 3 or more
4 4.5 or more
ø3 or more
5.6
or less
4 4.5 or more
Manufacturer
Model No.
Model No.
J.S.T. Mfg. Co.,Ltd
1.25-C3A
1.25-3
NICHIFU TERMINAL
INDUSTRIES CO.,LTD
1.25Y-3N
1.25-3
Nippon Tanshi Co., Ltd.
VD1.25-3
R1.25-3
• When using the above crimp terminals, the suitable wire conductor
cross-section area is 0.25 to 1.65mm
2
.
• The tightening torque should be 0.3 to 0.5N·m.
• Since the terminal block is divided into upper and lower levels, please
make connection to the lower level first.
Screwdriver
RELAY REPLACEMENT
5
● The relay has an electrical, as well as, a mechanical life.
In case there is any difficulty in operation due to relay contact wear and
tear or contact welding, replace the relay.
● If a relay other than the following described is used, the product may
break. Make sure to use the relay described below.
Manufacturer
Product Name.
Part
No.
Panasonic Co., Ltd.
PA-N relay
APAN3124
PhotoMos relay
Power voltage driving
type for both AC and DC
AQZ202D
AQZ204D
AQZ205D
AQZ207D
For the product’s characteristics when using PhotoMOS relay, refer to “
MOUNTING
.”
● Using the attached relay removal key, replace the relay as per the proce-
dure given below.
1. Align and insert the relay removal key in
the socket groove of the relay to be re-
moved.
Relay remover key
Insert
Relay to be replaced
Pull up
Slide
Insert
reliably
New relay
2. Pull up the relay removal key to remove
the relay from the relay socket.
3. Slide the relay removal key sideways to
detach the relay from the key.
4. Insert the new relay reliably into the socket,
matching the socket terminal direction.
https://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN
© Panasonic Industrial Devices SUNX Co., Ltd. 2018
INTENDED PRODUCTS FOR CE MARKING
8
● The models listed under “
SPECIFICATIONS
” come with
CE Marking. As for all other models, please contact our office.