QUICK INSTRUCTION MANUAL
Non-Contact Safety Door Switch
Maintenance Actuator SG-PK-M
Ƒ
Series
CMJE-SGPKM No.0077-18V
Thank you very much for purchasing Panasonic products. Read this Instruction Man-
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference.
7KLVGRFXPHQWEULHÀ\VXPPDUL]HVLQVWDOODWLRQDQGRSHUDWLRQRIWKHSURGXFW
When using the product, refer to the
SG-P
Series Instruction Manual in addition to
this manual.
The
SG-P
Series Instruction Manual can be downloaded from our website (https://
panasonic.net/id/pidsx/global).
Use this product together with the Non-contact Safety Door Switch
SG-P
Series.
When using the
SG-P
Series, refer to the
SG-P
Series Quick Instruction Manual
and
SG-P
Series Instruction Manual.
1
SAFETY CAUTIONS
Always observe
This section explains important rules that must be observed to prevent personal
injury and property damage.
Ŷ 7KHKD]DUGVWKDWPD\RFFXULIWKHSURGXFWLVXVHGLQFRUUHFWO\DUHGHVFULEHGDQG
FODVVL¿HGE\OHYHORIKDUP
WARNING Risk of death or serious injury.
CAUTION
Risk of minor injury or property damage.
WARNING
Ɣ
Machine designer, installer, employer and operator
• The machine designer, installer, employer and operator are solely responsible
to ensure that all applicable legal requirements relating to the installation and
WKHXVHRIWKLVGHYLFHLQDQ\DSSOLFDWLRQDUHVDWLV¿HGDQGDOOLQVWUXFWLRQVIRULQ
-
stallation and maintenance contained in the instruction manual are followed.
• Whether this device functions as intended to and systems including this de-
vice comply with safety regulations depends on the appropriateness of the ap-
plication, installation, maintenance and operation. The machine designer, in-
staller, employer and operator are solely responsible for these items.
Ɣ
Engineer
• The engineer would be a person who is appropriately educated, has wide-
spread knowledge and experience, and can solve various problems which
may arise during work, such as a machine designer, installer or employer etc.
Ɣ
Operator
• The operator should read this instruction manual thoroughly, understand its
contents, and perform operations following the procedures described in this
manual for the correct operation of this device.
• In case this device does not perform properly, the operator should report this to
the person in charge and stop the machine operation immediately. The machine
PXVWQRWEHRSHUDWHGXQWLOFRUUHFWSHUIRUPDQFHRIWKLVGHYLFHKDVEHHQFRQ¿UPHG
Ɣ
Environment
• This device is suitable for indoor use only.
• Do not use this device in an explosion-proof area.
• Do not install this device in the following places:
1) Areas with high humidity where condensation is likely to occur
2) Areas exposed to corrosive or explosive gases
3) Areas exposed to contact with water
4) Areas exposed to too much steam or dust
• Do not use this device near equipment that emits strong electromagnetic
waves.
Ɣ
Machine in which this device is installed
• Do not install this device with a machine whose operation cannot be stopped im-
mediately in the middle of an operation cycle by an emergency stop equipment.
Ɣ
Maintenance
• When replacement parts are required, always use only genuine supplied re-
placement parts. Using substitute parts from another manufacturer may cause
the device not to detect objects, resulting in death or serious injury.
• The periodical inspection of this device must be performed by an engineer
having the special knowledge.
• Clean this device with a clean cloth. Do not use any volatile chemicals.
Ɣ
Other precautions
•
1HYHUPRGLI\WKLVGHYLFH0RGL¿FDWLRQPD\FDXVHWKHGHYLFHQRWWRGHWHFWRE
-
jects, resulting in death or serious injury.
CAUTION
6SHFL¿FDWLRQV
Ɣ
This product has been developed / produced for industrial use only.
Ɣ
'RQRWXVHWKLVSURGXFWRXWVLGHWKHUDQJHRIWKHVSHFL¿FDWLRQV5LVNRIDQDFFLGHQW
and product damage. There is also a risk of a noticeable reduction of service life.
Ɣ
Use this device by installing suitable protection equipment as a countermeasure
for failure, damage, or malfunction of this device.
Ɣ
Before using this device, check whether the device performs properly with the
IXQFWLRQVDQGFDSDELOLWLHVDVSHUWKHGHVLJQVSHFL¿FDWLRQV
Ɣ
Note that this device may be damaged if it is subject to a strong shock (if it is
GURSSHGRQWRWKHÀRRUIRUH[DPSOH
Ɣ 'RQRWXVHWKHGHYLFHQHDUDQDSSDUDWXVWKDWJHQHUDWHVPDJQHWLF¿HOGV2WKHU
-
ZLVHWKHRSHUDWLQJGLVWDQFHPD\EHDႇHFWHG
Ɣ
Do not apply an excessive shock to the safety switch when opening or closing
the door.
Ɣ
Use of this device under the following conditions or environments is not presup-
posed. Please consult us if there is no other choice but to use this device in such
an environment.
1) Operating this device under conditions or environments not described in this
manual.
8VLQJWKLVGHYLFHLQWKHIROORZLQJ¿HOGVQXFOHDUSRZHUFRQWUROUDLOURDGDLU
-
craft, auto mobiles, combustion facilities, medical systems, aerospace devel-
opment, etc.
Ɣ
When the apparatus that uses this device is to be used for enforcing protection of a
person from any danger occurring around the area where machines are operated,
the user should satisfy the regulations established by national or regional security
committees (Occupational Safety and Health Administration: OSHA, the European
&RPPLWWHHIRU6WDQGDUGL]DWLRQHWF&RQWDFWWKHUHODWLYHRUJDQL]DWLRQVIRUGHWDLOV
Other precautions
Ɣ
Never attempt to disassemble, repair, or modify the product.
Ɣ
When this device becomes inoperable or unnecessary, dispose of the product
properly as industrial waste by abiding by the applicable law in the country.
2
CONTENTS OF PACKAGE
Actuator body: 1 unit
Quick Instruction Manual (English / Japanese, Chinese): 1 volume each
3
PRODUCT CONFIGURATION
Installing this product directly on the switch body enables a distinction from an abnor-
mal door open state.
This product is available in two types: one is a collective maintenance type (
SG-PK-
M1
) and the other is an individual maintenance type [
SG-PK-M2
(Note)].
Note: Multiple units of the individual maintenance type (
SG-PK-M2
) can be installed at the same time.
<When installing on the compact type (bottom)>
<When installing on the visible type>
Switch body
This product
Switch body
This product
Ɣ
The collective maintenance type (
SG-PK-M1
) can be installed only on the switch
body (standard).
Ɣ
The individual maintenance type (
SG-PK-M2
) can be installed on either the
switch body (standard) or switch body (sub).
Ɣ
When using this product, it is not possible to use the redundant input monitoring
(dual channel monitoring) with the
SG-P
Series OSSD1 and OSSD2 using the
safety controllers, etc.
Ɣ
When using the maintenance actuator, make sure that the normal actuator is not
detected at the same time.
Ɣ
Use the product with a system that distinguishes between the normal mode and
maintenance mode.
4
NAME OF PARTS
For details of the switch body, refer to the
SG-P
Series Quick Instruction Manual
and
SG-P
Series Instruction Manual.
Key ring mounting hole
Model No. printing
Release lever
Fixing claw
(Bottom side)
Fixing claw
(Top side)
Actuator detection surface
5
MOUNTING AND REMOVAL
The procedures to mount this product on the switch body or to remove it from the
switch body are as follows.
Visible type
Ɣ
Mounting procedure
1.
)LWWKH¿[LQJFODZERWWRPVLGHIURPWKHIURQWVLGHRIWKHVZLWFKERG\DORQJWKH
root of the cable.
1
2.
3XVKLQWKH¿[LQJFODZWRSVLGHWRVHFXUHLWRQWKHVZLWFKERG\
2
Ɣ
Removal procedure
When removing this product from the switch body, push in the release lever located
ULJKWEHORZWKH¿[LQJFODZWRSVLGHWROLIWWKH¿[LQJFODZ
:KLOHWKH¿[LQJFODZLVOLIWHGSXOORXWWKHSURGXFWWRUHPRYHLWIURPWKHVZLWFKERG\
Pull out
Push in
Note: Do not hold and pull any part of the product other than the release lever when removing it from the switch body.
Doing so will cause a failure or damage.