38
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
English
3. Functional Description
<Common to emitter and receiver>
Description
Function
Beam-axis align-
ment indicator
(Red / Green)
A
<Wiring synchronization using 8-core cable>
When device top receives light: lights up in red
When device top end receives light: blinks in red
When control output (OSSD 1 / 2) is ON: lights up in green
<Beam synchronization using 4-core cable>
Always OFF
B
<Wiring synchronization using 8-core cable>
When device upper middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
<Beam synchronization using 4-core cable>
Always OFF
C
<Wiring synchronization using 8-core cable>
When device lower middle receives light: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
<Beam synchronization using 4-core cable>
Always OFF
D
<Wiring synchronization using 8-core cable>
When device bottom receives light: lights up in red
When device bottom end receives light: blinks in red
When control output (OSSD 1 / 2) is ON: lights up in green
<Beam synchronization using 4-core cable>
Always OFF
Fault indicator (Yellow) When fault occurs in the device: lights up or blinks
<Emitter>
Description
Function
Operation indicator
(Red / Green)
<Wiring synchronization using 8-core cable>
When control output (OSSD 1 / 2) is OFF: lights up in red
When control output (OSSD 1 / 2) is ON: lights up in green
<Beam synchronization using 4-core cable>
When an error occurs in emitter: lights up in red
When emitter operates normally: lights up in green
Emission halt indicator
(Orange)
When light emission is halt: lights up
When light is emitted: turns OFF
Setting indicator (Red)
<Wiring synchronization using 8-core cable>
Always OFF
<Beam synchronization using 4-core cable>
When frequency 1 is set: One bar lights up
When frequency 2 is set: Two bars light up
<Receiver>
Description
Function
OSSD indicator
(Red / Green)
Lights up in red when control output (OSSD 1 / 2) is OFF.
Lights up in green when control output (OSSD 1 / 2) is ON.
Incident light intensity
indicator
(Green / Orange)
When sufficient light is received (Incident light:
130% or more): lights up in green
When stable light is received (Incident light: 115 to
130%): OFF
When unstable light is received (Incident light : 100
to 115%): lights up in orange
When light is blocked: OFF
Digital error indicator
(Red)
<Wiring synchronization using 8-core cable>
When device goes into lockout condition, error contents are indicated.
<Beam synchronization using 4-core cable>
When device goes into lockout condition, error contents are indicated.
When frequency 1 is set: The middle bar lights up
When frequency 2 is set: The middle bar and the bottom bar light up
Location of beam-axis
alignment indicator
Indicator section of receiver
OSSD indicator
Beam-axis alignment
indicator
Incident light intensity indicator
Fault indicator
Digital error indicator
Indicator section of emitter
Fault indicator
Emission halt indicator
Beam-axis alignment
indicator
Operation indicator
Setting indicator
Содержание SF2B Series
Страница 99: ... MEMO ...
Страница 100: ......