2-2 Mounting
2-2-1 Mounting of the Mounting Bracket
<Reference>
•
Mount the emitter and the receiver at the same level and parallel to each other. The effective
aperture angle of this device is ±5° or less for a sensing distance of 3m or more.
•
Unless otherwise specified, the following mounting procedure is common for both emitter and
receiver. For the mounting, prepare the mounting holes on the mounting surface by referring to
<When the standard mounting bracket (MS-SF2B-1) (optional) is used>
Configuration
The standard mounting bracket (
MS-SF2B-1
) (optional) configures as follows.
1. Fix the standard mounting bracket with two hexagon-socket head bolts [M3 (length:
5mm)]. The tightening torque should be 0.6N·m or less.
2. For side mounting, remove the B part.
•
For selecting the appropriate mounting bracket matched to the installation
environment, the mounting bracket is not incorporated in this device. Please
purchase the optional mounting bracket to fit on the mounting environment.
•
Do not apply the load such as forced bending to the cable of this device.
Applying improper load could cause the wire breakage.
•
The minimum bending radius of the cable is R6mm. Mount the device
considering the cable bending radius.
Содержание SF2B-H80SL
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2021 2 MEMO ...
Страница 22: ... Panasonic Industrial Devices SUNX Co Ltd 2021 22 Min sensing object φ47mm 40mm pitch type ...
Страница 25: ... Panasonic Industrial Devices SUNX Co Ltd 2021 25 3 2 2 Side Mounting with Standard Mounting Bracket MS SF2B 1 ...
Страница 28: ... Panasonic Industrial Devices SUNX Co Ltd 2021 28 MEMO ...