28
ICX (International), issued March/1998
ICX-35-700
Chapter 3. System Features
Section 700 - Operation
Caller ID Alpha Tagging (Not Available in USA)
CPC-96, CPC-288, and CPC-576 Version 3.0
Description
If the received Caller ID phone number matches any number in the System Speed Dials (SSD)
(SSD000-SSD199), then the associated SSD name can be displayed as the Caller ID information
instead of the Caller ID phone number. Alternatively, the Direct Dial Inward (DDI) name may be
displayed instead.
Hardware Requirements
•
Loop-start trunk card (VB-44510)
•
Caller ID circuit card (VB-44513)
Considerations
•
The system may be set to display Caller ID in one of two priorities as follows:
Priority Choice 1
• CID name (future feature)
• Alpha tagging if matched
• DDI name
Priority Choice 2
• DDI name
• CID name (future feature)
• Alpha tagging if matched
•
Currently Caller ID only supports the single format (number only). Multiple format (number and
name) is not currently available but is planned as a future feature.
•
Caller ID Call Logging only shows the CID number.
Centrex/PBX Compatibility
Description
Centrex/PBX Compatibility allows the System to be connected behind centrex or PBX lines.
The System supports up to 6 access codes for dialling centrex or a PBX. These access codes allow the
System, System Message Detail Recording (SMDR) (Call Logging) output to exclude the number
dialled to reach a centrex or PBX line.
When connected behind a PBX or Centrex, Toll Restriction Service (TRS) (Call Barring) can be used
to restrict calls.
The System also supports transmission of a flash signal over the centrex or PBX link.
Hardware Requirements
•
N/A
Considerations