2.3. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
·
No sound is heard when the power is turned on.
·
Stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
1. Turn off the power.
2. Determine the cause of the problem and correct it.
3. Turn on the power once again after one minute.
Note:
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
2.4. Safety Part Information
Safety Parts List:
There are special components used in this equipment which are important for safety.These parts are marked by
in the
Schematic Diagrams & Replacement Parts List. It is essential that these critical partsshould be replaced with manufacturer’s
specified parts to prevent shock, fire or other hazards. Do not modify the original designwithout permission of manufacturer.
Table 1
Reference No.
Part No.
Part Name & Description
Remarks
A1
K2CB2CB00018
AC CORD
18
N0AB6GY00001
SMPS MODULE
5
SH-FX65P / SH-FX65PC
Содержание SE-FX65P
Страница 10: ...6 4 Making the wireless link SE FX65 10 SH FX65P SH FX65PC ...
Страница 31: ...12 2 Waveform Chart RF TEST POINT PLAY 31 SH FX65P SH FX65PC ...
Страница 36: ...SH FX65P SH FX65PC 36 ...
Страница 38: ...38 SH FX65P SH FX65PC ...
Страница 54: ...54 SH FX65P SH FX65PC ...
Страница 55: ...20 Exploded Views 20 1 Cabinet Parts Location SH FX65P SH FX65PC 55 ...
Страница 56: ...20 2 Packaging 20 2 1 Packaging Condition For SH FX65P PC S SH FX65P SH FX65PC 56 ...