1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
(This “Safety Precaution” is applied only in U.S.A.)
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only manufacturer’s recommended components for safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the
customer from being exposed to a shock hazard.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
W
and 5.2M
W
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
1.1.2. Leakage Current Hot Check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
W
, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
Fig. 1
4
SC-EN37P
Содержание SC-EN37P
Страница 10: ...6 Accessories Remote Control AC Cord FM AM Antenna I Pod cradle 10 SC EN37P ...
Страница 12: ...7 3 Connection 12 SC EN37P ...
Страница 30: ...11 1 Check and Repair of CD Servo P C B 30 SC EN37P ...
Страница 33: ...12 2 CD Servo P C B 12 3 Motor P C B 12 4 Panel P C B 12 5 Tuner P C B 33 SC EN37P ...
Страница 34: ...12 6 Waveform Chart 34 SC EN37P ...
Страница 35: ...13 Wiring Connection Diagram 35 SC EN37P ...
Страница 36: ...SC EN37P 36 ...
Страница 37: ...14 Block Diagram 14 1 CD Servo SC EN37P 37 ...
Страница 38: ...14 2 Tuner SC EN37P 38 ...
Страница 39: ...14 3 Main 1 2 Transformer Sensor D Port SC EN37P 39 ...
Страница 40: ...14 4 Main 2 2 Panel LED Power Switch Tact Switch Switch Motor SC EN37P 40 ...
Страница 42: ...42 SC EN37P ...
Страница 44: ...16 1 A CD Servo Circuit SC EN37P 44 ...
Страница 45: ...16 2 B Tuner Circuit SC EN37P 45 ...
Страница 46: ...16 3 C Main Circuit SC EN37P 46 ...
Страница 47: ...SC EN37P 47 ...
Страница 48: ...SC EN37P 48 ...
Страница 49: ...16 4 D Panel Circuit E D Port Circuit SC EN37P 49 ...
Страница 50: ...16 5 F LED Circuit G Power Switch Circuit H Tact Switch Circuit I Switch Circuit SC EN37P 50 ...
Страница 51: ...16 6 J Motor Circuit K Sensor Circuit L Transformer Circuit SC EN37P 51 ...
Страница 52: ...SC EN37P 52 ...
Страница 54: ...SC EN37P 54 17 2 C Main P C B ...
Страница 55: ...55 17 3 D Panel P C B E D Port P C B F LCD P C B G Power Switch P C B H Tact Switch P C B SC EN37P ...
Страница 56: ...SC EN37P 56 17 4 I Switch Circuit P C B J Motor Circuit P C B K Sensor Circuit P C B L Transformer P C B ...
Страница 57: ...17 4 I Switch Circuit P C B J Motor Circuit P C B K Sensor Circuit P C B L Transformer P C B SC EN37P 57 ...
Страница 58: ...SC EN37P 58 ...
Страница 59: ...18 Illustration of ICs Transistors and Diodes 59 SC EN37P ...
Страница 61: ...20 Exploded Views 20 1 Cabinet Parts Location SC EN37P 61 ...
Страница 62: ...SC EN37P 62 ...
Страница 63: ...20 2 Packaging SC EN37P 63 ...
Страница 64: ...SC EN37P 64 ...