8.3. DVD Self Diagnostic Function-Error Code
8.3.1. Mechanism Error Code Table
Error
Code
H01 Tray loading error
The tray opening and closing is
Press [ STOP] on
abnormal. CLOSE and OPEN of the
main unit for next error.
tray cannot be carried out properly.
(OPEN time: OPEN
Loading motor error, DV5 LSI IC
CLOSE OPEN
(IC8001) error.
H01 at CLOSE: CLOSE
OPEN CLOSE
H01)
H02 Spindle servo error
The spindle servo/motor is abnormal.
Press [ STOP] on
The FG pulse is abnormal. CLV servo
main unit for next error.
error.
H03 Traverse servo error The traverse is abnormal. (Traverse
Press [ STOP] on
servo, DV5 LSI IC (IC8001), TRV
main unit for next error.
motor error.)
H04 Tracking servo error Tracking coil NG (OPU unit
Press [ STOP] on
abnormal), DV5 LSI IC (IC8001)
main unit for next error.
error.
H05 Seek time out error
It is not possible to access the disc.
Press [ STOP] on
TOC cannot read. Abnormal disc etc.
main unit for next error.
Pickup abnormal or disk is dirty.
(TRV motor error, DV5 LSI IC
(IC8001) error.)
H07 Driver IC thermal
The spindle motor is abnormal. (short
Press [ STOP] on
shut down
between brushes)
main unit for next error.
H15 Disc tray open
The disc tray cannot be opened & it
Press [ STOP] on
detection switch
closes spontaneously.
main unit for next error.
failure
H16 Disc tray close
The disc tray cannot be closed & it
Press [ STOP] on
detection switch
opens spontaneously.
main unit for next error.
failure
U11 Focus servo error
Focus coil, FE signal error.
Press [ STOP] on
main unit for next error.
(Unfinalized DVD-R
U15 Unfinalized DVD-R
is likely to beocme U11.)
F500 DSC error
DV5 LSI IC (IC8001) stops in the
Press [ STOP] on
occurance of servo error (startup,
main unit for next error.
focus error, etc)
F506 Invalid media
Disc is flipped over, TOC unreadable,
Press [ STOP] on
incompatible disc.
main unit for next error.
F620 OPU unit
Laser protection at high temperature.
Press [ STOP] on
abnormality
main unit for next error.
temperature
F621 OPU unit
Laser protection at circuit failure.
Press [ STOP] on
circuitry
main unit for next error.
temperature
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
29
SA-PT250GCP
Содержание SA-PT250EE
Страница 5: ...25 Replacement Parts List 108 25 1 Component Parts List 109 5 SA PT250GCP ...
Страница 12: ...12 SA PT250GCP ...
Страница 36: ...9 2 Main Components and P C B Locations 36 SA PT250GCP ...
Страница 51: ...Step 3 Remove the middle chassis Step 4 Remove the traverse unit 51 SA PT250GCP ...
Страница 66: ...SA PT250GCP 66 ...
Страница 74: ...SA PT250GCP 74 ...
Страница 76: ...76 SA PT250GCP ...
Страница 104: ...24 Exploded Views 104 SA PT250GCP ...
Страница 105: ...24 1 Cabinet Parts Location SA PT250GCP 105 ...
Страница 106: ...SA PT250GCP 106 ...
Страница 107: ...24 2 Packaging SA PT250GCP 107 ...