1.2. Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C2602, C2641, C2642, C5015, C5016, C5110, C5916, C5917 and
C5938 through a 10
Ω
, 1W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
•
Current consumption at AC 230-240 V, at 50 Hz in NO SIGNAL mode (at volume min) should be ~300 mA.
1.3. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
•
No sound is heard when the power is turned on.
•
Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
"shorted", or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
1. Turn off the power.
2. Determine the cause of the problem and correct it.
3. Turn on the power once again after one minute.
Note:
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
1.4. Safety Part Information
Safety Parts List:
There are special components used in this equipment which are important for safety.These parts are marked by
in the
Schematic Diagrams & Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer’s
specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer.
Table 1
Reference No.
Part No.
Part Name & Description
Remarks
A2
K2CJ2DA00008
AC CORD
[M]
JK5970
K2AA2B000017
AC INLET
[M]
T5900
G4CYAYY0 0174
POWER TRANSFORMER
[M]
T5901
G4CYAYY0 0137
SUB-TRANSFORMER
[M]
F5970
K5D162BLA013
FUSE
[M]
L5970
ELF15N035AN
LINE FILTER
[M]
RL5970
K6B1AEA00003
POWER RELAY
[M]
Z5970
ERZVA5Z471
ZENER
[M]
FP5920
K5G402AA0002
FUSE PROTECTOR
[M]
FP5922
K5G202AA0002
FUSE PROTECTOR
[M]
22
RFKHAPMX3GNS
REAR CABINET ASS´Y
[M]
21
RKMX0142-S
TOP CABINET
[M]
PCB1
REPX0633A
TRANSFORMER P.C.B.
[M]
(RTL)
301
RAEX0190Z-V
TRAVERSE UNIT
[M]
(RTL)
4
SA-PMX3GN
Содержание SA-PMX3GN
Страница 10: ...6 Operation Procedures 6 1 Main Unit Key Buttons Operation 10 SA PMX3GN ...
Страница 11: ...6 2 Remote Control Key Buttons Operation 6 3 Disc Information 11 SA PMX3GN ...
Страница 18: ...18 SA PMX3GN ...
Страница 20: ...8 2 Main Parts Location Diagram 20 SA PMX3GN ...
Страница 56: ...56 SA PMX3GN ...
Страница 58: ...SA PMX3GN 58 ...
Страница 64: ...SA PMX3GN 64 ...
Страница 66: ...66 SA PMX3GN ...
Страница 86: ...SA PMX3GN 86 ...
Страница 91: ...20 Exploded Views 20 1 Cabinet Parts Location SA PMX3GN 91 ...
Страница 92: ...20 2 Packaging SA PMX3GN 92 ...