17
6.3.3.
Doctor Mode Table 3
Display of Bluetooth MAC Address will
scroll forever
Bluetooth Address Check
Bluetooth Mac
Address Checking
Press [
] follow by [3] & then [1]
button on the remote control.
In Doctor Mode:
Select to the Bluetooth Mode
•
To exit Doctor Mode, press
[DEL]
button on the remote control without
power off.
• Unplug the AC cord.
To cancel, press [0] button on remote
control. [CANCEL] will be display and
returns to Doctor Mode.
Item
FL Display
Key Operation
Mode Name
Description
Front Key
The [NO DISC] display will appear after 2s.
During updating, FL will blink “Updating”
Then FL will display “Network”
Note : During updating,
nokey is valid.
If main unit finish updating successfully,
FL will scroll “ Network Initializing” until
initialization finished
Press [
] follow by [1] & then [6]
button on the remote control.
AD value of region pin is check and display
will show [REG ON_YY] based on region
table.
YY = 1 ~ 15 based on region table as below.
Checking for model no and
Region
Region Check
ALLPLAY
Firmware Update
Note: ALLPLAY module
initialization must finish before
enter this test mode.
1. Necessary items
(a) PC with tftp server setting
(b) Cross over LAN cable
(c) AllPlay firmware file (Eg.
sam-mcu-s-all7cd-103.sam)
(d) DTB file (Eg. all-sam-pana-
all7cddab.mft)
2. Preparation on PC and network
setting
(a) Put AllPlay firmware file and DTB
file on tftp folder in PC
(b) Set IP address of PC to
“172.19.42.100”. IP address
“172.19.42.101” is for PMX150 main
unit. Tester don’t have to set that
manually.
(c) Connect main unit to PC with LAN
cable directly
ALLPLAY
Firmware
In Doctor Mode:
•
To exit Doctor Mode, press
[DEL]
button on the remote control without
power off.
• Unplug the AC cord.
To cancel, press [0] button on remote
control. [CANCEL] will be display and
returns to Doctor Mode.
1) Change to Network selector.
2) Press [SOUND] button on the
remote control.
In Doctor Mode:
•
To exit Doctor Mode, press
[DEL]
button on the remote control without
power off.
• Unplug the AC cord.
To cancel, press [0] button on remote
control. [CANCEL] will be display and
returns to Doctor Mode.
If updating fail, FL will display“Fail”
Region
DBEB, DBGN
DBEG
EG
PC
DBEB
(For DAB)
(For DAB)
(For DAB - PMX82M model)
Value (Y)
15
1
14
10
0
Содержание SA-PMX150
Страница 12: ...12 5 Location of Controls and Components 5 1 Main Unit Remote Control Key Button Operations ...
Страница 27: ...27 8 3 Main Parts Location Diagram ...
Страница 50: ...50 ...
Страница 52: ...52 ...