20
7.3.
Error Code Table
Self-Diagnosis Function provides information on any problems occuring for the unit and its respective components by displaying
error codes. Thesed error code such as U**, H** and F** are stored in memory and held unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
Error Code
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
H15
CD Open SW Abnormal
During normal operation
CD OPEN SW On fail to be
detected with 4 sec. Error
No. shall be clear by force
or during cold start.
For CD Mechanism Unit
(DLS6C).
Press [
] on main
unit for next error.
F15
CD REST SW Abnormal
CD traverse position intial
setting operation failsafe
counter (1000 ms) waiting
for REST SW to turn on.
Error No. shall be clear by
force or during cold start.
For CD Mechanism Unit
(DLS6C).
Press [
] on main
unit for next error.
F26
Communication between
CD servo LSI and micro-p
abnormal.
CD function DTMS com-
mand, after system set-
ting, If SENSE = 'L' cannot
be detected. Memory shall
contain F26 code. After
Power on, CD function
shall continue, error dis-
play shall be "NO DISC".
Error No. shall be clear by
force or cold start.
For CD Mechanism Unit
(DLS6C).
Press [
] on main
unit for next error.
F76
Power Amp IC output
abnormal
DCDET1 = L (NG)
For power.
Press [
] on main
unit for next error.
Содержание SA-PM38DBEB
Страница 4: ...4 1 2 Caution for AC Cord ...
Страница 13: ...13 5 Location of Controls and Components 5 1 Main Unit Key Button Operations ...
Страница 14: ...14 5 2 Remote Control Key Button Operations ...
Страница 15: ...15 6 Operating Instructions 6 1 Disc Information ...
Страница 21: ...21 8 Troubleshooting Guide ...
Страница 25: ...25 10 2 Main Parts Location Diagram ...