1 Safety Precautions
1.1. GENERAL GUIDELINES
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, carry out the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1.
LEAKAGE CURRENT COLD CHECK
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
Figure 1
1.1.2.
LEAKAGE CURRENT HOT CHECK (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15µF capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is outside of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
1.2. Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C5701, C5706, C5714, C5736 & C5737 through a 10
Ω
, 10 W resistor
to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 230 V, 50 Hz in NO SIGNAL mode (at volume minimum) should be ~ 900 mA.
1.3. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
·
No sound is heard when the power is turned on.
·
Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
6
SA-HT995EE
Содержание SA-HT995EE
Страница 3: ...Refer to the original service manual for 1 2 3 4 3 SA HT995EE ...
Страница 11: ...11 SA HT995EE ...
Страница 14: ...7 2 Main Unit Key Buttons Operations SA HT995 SURROUND ENHANCER 14 SA HT995EE ...
Страница 16: ...7 4 Using of Music Port MONO ST E AC G H B SR H W 16 SA HT995EE ...
Страница 18: ...7 5 2 File Extension Type Support WMA MP3 JPEG MPEG4 DivX 18 SA HT995EE ...
Страница 19: ...7 6 About DivX VOD Content 19 SA HT995EE ...
Страница 21: ...8 New Features 8 1 About HDMI 8 1 1 What is HDMI 8 1 2 Advanced Digital Pictures 21 SA HT995EE ...
Страница 22: ...8 1 3 Advanced Digital Sound 8 1 4 Easy to Use 8 1 5 HDMI Compatible Products 22 SA HT995EE ...
Страница 27: ...27 SA HT995EE ...
Страница 33: ...10 1 Disassembly Flow Chart 33 SA HT995EE ...
Страница 34: ...10 2 Main Components and P C B Locations 34 SA HT995EE ...
Страница 62: ...SA HT995EE 62 ...
Страница 70: ...SA HT995EE 70 ...
Страница 72: ...72 SA HT995EE ...
Страница 106: ...25 Exploded Views 25 1 Cabinet Parts Location 106 SA HT995EE ...
Страница 107: ...107 SA HT995EE ...
Страница 108: ...25 2 Packaging 108 SA HT995EE ...