Error
Code
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
F600
Access failure to
management information
caused by demodulation
error
Operation stopped because navigation
data is not accessible caused by the
demodulation defect
Press [
n
STOP] on main
unit for next error
F601
Indeterminate sector ID
requested
Operation
stopped
caused
by
the
request to access abnormal ID data
Press [
n
STOP] on main
unit for next error
F602
Access failure to LEAD-IN
caused by demodulation
error
LEAD IN data unreadable
Press [
n
STOP] on main
unit for next error
F603
Access failure to KEYDET
caused by demodulation
error
Access failure to CSS data of disc
Press [
n
STOP] on main
unit for next error
F610
ODC abnormality
No permission for command execution
Press [
n
STOP] on main
unit for next error
F611
No CRC OK for a specific
time (CD)
Access failure to seek address in CD
series
Press [
n
STOP] on main
unit for next error
F612
No CRC OK for a specific
time (DVD)
Access failure to ID data in DVD series
Press [
n
STOP] on main
unit for next error
F620
Laser safeguard: high
temperature condition
High temperature of the laser guide unit
(OPU unit)
Press [
n
STOP] on main
unit for next error
F621
Laser safeguard: circuit
failure condition
Circuitry failure of the laser guide unit
(OPU unit)
Press [
n
STOP] on main
unit for next error
F103
Illegal highlight Position
Big possibility of disc specification
violation during highlight display
Press [
n
STOP] on main
unit for next error
F4FF
Force initialize failure (time
out)
Timeout when force initialization fails
Press [
n
STOP] on main
unit for next error
F700
MBX overflow
When replying message to disc manager
Press [
n
STOP] on main
unit for next error
F701
Message command does
not end
Next message is sent before replying to
disc manager
Press [
n
STOP] on main
unit for next error
F702
Message command
changes
Message is changed before it is sent as
a reply to disc manager
Press [
n
STOP] on main
unit for next error
F880
Task number is not
appropriate
Message coming from a non-existing
task
Press [
n
STOP] on main
unit for next error
F890
Sending message when
message is being sent to
AV task
Sending message to AV task
Press [
n
STOP] on main
unit for next error
F891
Message couldn’t be sent
to AV task
Begin sending message to AV task
Press [
n
STOP] on main
unit for next error
33
SA-HT640WP / SA-HT640WPC
Содержание SA-HT640WP
Страница 7: ...7 SA HT640WP SA HT640WPC ...
Страница 10: ...10 SA HT640WP SA HT640WPC ...
Страница 16: ...16 SA HT640WP SA HT640WPC ...
Страница 19: ...8 2 Detail Block Diagram Receiver module 19 SA HT640WP SA HT640WPC ...
Страница 31: ...31 SA HT640WP SA HT640WPC ...
Страница 37: ...10 1 Disassembly Flow Chart 10 2 Main Components and P C B Locations 37 SA HT640WP SA HT640WPC ...
Страница 45: ...Step 3 Push tray assembly to the direction of arrow shown 45 SA HT640WP SA HT640WPC ...
Страница 58: ...SA HT640WP SA HT640WPC 58 ...
Страница 66: ...SA HT640WP SA HT640WPC 66 ...
Страница 68: ...68 SA HT640WP SA HT640WPC ...
Страница 78: ...SA HT640WP SA HT640WPC 78 ...
Страница 84: ...SA HT640WP SA HT640WPC 84 ...
Страница 86: ...SA HT640WP SA HT640WPC 86 ...
Страница 95: ... SMPS stands for switching mode power supply 95 SA HT640WP SA HT640WPC ...
Страница 102: ...21 3 4 2 Receiver Module P C B 102 SA HT640WP SA HT640WPC ...
Страница 104: ...23 Explode Views 23 1 Cabinet Parts Location 104 SA HT640WP SA HT640WPC ...
Страница 105: ...105 SA HT640WP SA HT640WPC ...
Страница 106: ...106 SA HT640WP SA HT640WPC ...
Страница 107: ...23 2 Packaging 107 SA HT640WP SA HT640WPC ...