3. After servicing, carry out the following leakage current checks to
prevent the customer from being exposed to shock hazards.
1.1.1. LEAKAGE CURRENT COLD CHECK
1. Unplug the AC cord and connect a jumper between the two prongs
on the plug.
2. Measure the resistance value, with an ohmmeter, between the
jumpered AC plug and each exposed metallic cabinet part on the
equipment such as screwheads, connectors, control shafts, etc.
When the exposed metallic part has a return path to the chassis,
the reading should be between 1M and 5.2M . / When the
exposed metal does not have a return path to the chassis, the
reading must be
.
Figure 1
1.1.2. LEAKAGE CURRENT HOT CHECK (See
Figure 1
.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k , 10 watts resistor, in parallel with a 0.15 F
capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in
Figure 1
.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at
6
Содержание SA-HT440P
Страница 12: ...6 Accessories Remote control AM loop antenna FM indoor antenna AC cord Video Cable 12 ...
Страница 15: ...8 1 2 Tips on using digital transmitter SH FX60T 15 ...
Страница 16: ...8 1 3 Below is tips on using digital receiver SB FX80 8 1 4 Tips on using digital transmitter SH FX80T 16 ...
Страница 19: ...9 3 DVD Self Diagnostic Function Error Code 19 ...
Страница 41: ...Step 2 Remove Drive Gear A and Drive Gear B 41 ...
Страница 64: ...64 ...
Страница 65: ...65 ...
Страница 66: ...23 2 Packaging 66 ...
Страница 74: ...LB8505 J0JCC0000119 CHIP INDUCTOR M 74 ...
Страница 85: ...R5709 ERJ6GEYJ222V 2 2K 1 10W M 85 ...
Страница 134: ...72 ...
Страница 135: ...72 ...
Страница 146: ...78 ...
Страница 147: ...78 ...