1. To check for correct insertion of flat cable.
Insert connector until you hear a click.
Make sure the white side of the cable is on your right side. Refer to
Fig. 6-2.
Fig. 6-2.
2. Breakage of flat cable. (Check and replace.)
3. If the problem is not corrected by items 1 and 2 above, this indicates a faulty IC.
SA-DT300:
IC941 (C2CBHG000095)
SL-DT300:
IC402 (C2BBFD000350)
Check these ICs and replace.
6.3.2 F61
Problem or condition
When the Standby/on switch is switched on, it automatically switches back off, making it impossible to switch
power on.
Correction procedure
Faulty AV control receiver (SA-DT300) power supply line or when a DC voltage is applied to speaker terminals.
(Check and replace.)
Page 2 of 2