Item
FL Display
Key Operation
Mode Name
Description
Front Key
CR14 inspection
CR14 inspection
operation:
1.
Load TRAY 1 (Move
to PLAY position)
2.
After that, TRAY 2 is
open (TRAY 1 still in
LOAD condition) and
close.
3.
Next TRAY 3 is open
(TRAY 1 still in
LOAD condition) and
close.
4.
Then TRAY 4 is
open (TRAY 1 still in
LOAD condition) and
close.
5.
Finally TRAY 5 is
open (TRAY 1 still in
LOAD condition) and
close.
6.
Tray 1 is unloaded.
(Move to the STOCK
position)
7.
Tray 1 is loaded.
(Move to the PLAY
position)
When step 1 to 7
operates normally without
any error, FL will display
[CHGR_OK_]
If operation without any error
If operation with error
If NG, please refer to the original service
manual of changer unit CR14C.
In doctor Mode:
1.
Press [DISC] button on remote control.
To exit Doctor Mode, press [
] button on
main unit or remote control.
7.2.3. Service Mode Table 3
Item
FL Display
Key Operation
Mode Name
Description
Front Key
Self Diagnostic
History
Checking the records for
self-diagnostic.
In service mode:
1.
Press [1] button on remote control.
To exit Service Mode, press [
] button on
main unit or remote control.
To clear history, press & hold [0] for 5 seconds
or more.
Micro-P Version
Display
Checking of various
items and firmware
version.
Note: The micro-
processor version as
shown is an example. It
will be revise when there
is an updates.
FL Display
sequenceDisplay [
]
(Display 1)
(Display 2)
In service mode:
1.
Press [2] button on remote control.
To exit Service Mode, press [
] button on
main unit or remote control.
Cold Start (Reset) To activate cold start
ipon next AC power up.
In service mode:
1.
Press [3] button on remote control.
To exit Service Mode, press [
] button on
main unit or remote control.
17
SA-AK870GCP
Содержание SA-AK870GCP
Страница 9: ...9 SA AK870GCP ...
Страница 11: ...6 Operation Procedures 6 1 Main Unit Key Buttons Operation 11 SA AK870GCP ...
Страница 12: ...6 2 Remote Control Key Buttons Operation 6 3 Disc Information 12 SA AK870GCP ...
Страница 13: ...6 4 Using the Music Port and Connecting Playing a USB Mass Storage Class Device 13 SA AK870GCP ...
Страница 14: ...14 SA AK870GCP ...
Страница 24: ...8 2 Main Parts Location Diagram 24 SA AK870GCP ...
Страница 37: ...37 SA AK870GCP ...
Страница 57: ...Step 5 Desolder 2 wires pins White and blue 57 SA AK870GCP ...
Страница 80: ...14 2 Waveform Chart 80 SA AK870GCP ...
Страница 82: ...SA AK870GCP 82 ...
Страница 92: ...92 SA AK870GCP ...
Страница 118: ...SA AK870GCP 118 ...
Страница 123: ...22 Exploded Views 22 1 Cabinet Parts Location Traverse Parts Location SA AK870GCP 123 ...
Страница 124: ...SA AK870GCP 124 ...
Страница 125: ...22 2 Deck Mechanism Parts Location RAA4407 S SA AK870GCP 125 ...
Страница 126: ...22 3 Packaging SA AK870GCP 126 ...