1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
(This “Safety Precaution” is applied only in U.S.A.)
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only manufacturer’s recommended components for safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the
customer from being exposed to a shock hazard.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
1.1.2. Leakage Current Hot Check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
Fig. 1
1.2. Before repair and adjustment
Disconnect AC power, discharge Power Capacitors C5101, C5104, C5171, C5172, C5920, C5940 and C5950 through a 10
Ω
, 5W
resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 120V, 60 Hz in NO SIGNAL mode (volume min at CD mode) should be ~ 500mA.
4
SA-AK750PL
Содержание SA-AK750PL
Страница 8: ...8 SA AK750PL ...
Страница 11: ...6 Accessories Remote Control FM Antenna Wire AC Cord AM Loop Antenna 11 SA AK750PL ...
Страница 13: ...13 SA AK750PL ...
Страница 15: ...With reference to page 15 of the operating instruction manual 15 SA AK750PL ...
Страница 16: ...With reference to page 16 of the operating instruction manual 16 SA AK750PL ...
Страница 27: ...10 3 Main Parts Location 27 SA AK750PL ...
Страница 39: ...10 17 1 Replacement of Pinch Roller and Head Block 39 SA AK750PL ...
Страница 40: ...10 17 2 Replacement of Motor Capstan Belt A Capstan Belt B and Winding Belt 40 SA AK750PL ...
Страница 46: ...12 4 Checking and Repairing of Power P C B 46 SA AK750PL ...
Страница 48: ...48 SA AK750PL ...
Страница 52: ...15 3 Power P C B Transformer P C B 15 4 Panel P C B 52 SA AK750PL ...
Страница 53: ...15 5 Main P C B 53 SA AK750PL ...
Страница 54: ...15 6 Deck P C B 15 7 Waveform Chart 54 SA AK750PL ...
Страница 56: ...56 SA AK750PL ...
Страница 64: ...SA AK750PL 64 ...
Страница 66: ...66 SA AK750PL ...
Страница 86: ...SA AK750PL 86 ...
Страница 91: ...23 Exploded Views 23 1 Cabinet Parts Location SA AK750PL 91 ...
Страница 92: ...SA AK750PL 92 ...
Страница 93: ...23 2 Deck Mechanism Parts Location RAA4403 S SA AK750PL 93 ...
Страница 94: ...23 3 Packaging SA AK750PL 94 ...