1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, ensure that all the protective devices such as insulation barriers and insulation papers shields are properly
installed.
3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
.
1.1.2. Leakage Current Hot Check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. Should the measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
Fig. 1
1.2. Before Use
Be sure to disconnect the mains cord before adjusting the voltage selector.
Use a minus(-) screwdriver to set the voltage selector (on the rear panel) to the voltage setting for the area in which the unit will
be used. (If the power supply in your area is 110V or 127V, set to the “127V” position.)
Note that this unit will be seriously damaged if this setting is not made correctly. (There is no voltage selector for some countries,
the correct voltage is already set.)
1.3. Before repair and adjustment
Disconnect AC power, discharge power capacitors C5101, C5104, C5171, C5172, C5920, C5940 and C5950 through a 10
Ω
, 5W
resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 110 ~ 127V, 50 Hz in NO SIGNAL mode (at volume min at CD mode) should be ~ 500mA.
Current consumption at AC 220 ~240V, 60 Hz in NO SIGNAL mode (at volume min at CD mode) should be ~ 350mA.
1.4. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
4
SA-AK250GCP
Содержание SA-AK250GCP
Страница 8: ...8 SA AK250GCP ...
Страница 12: ...7 Operating Procedures 7 1 Main Unit Key Buttons Operations 12 SA AK250GCP ...
Страница 13: ...7 2 Remote Control Key Buttons Operations 13 SA AK250GCP ...
Страница 15: ...With reference to page 15 of the operating instruction manual 15 SA AK250GCP ...
Страница 17: ...17 SA AK250GCP ...
Страница 20: ...20 SA AK250GCP ...
Страница 22: ...9 4 2 Error Code Table For CD Changer Block 22 SA AK250GCP ...
Страница 23: ...23 SA AK250GCP ...
Страница 24: ...24 SA AK250GCP ...
Страница 28: ...10 3 Main Parts Location 28 SA AK250GCP ...
Страница 37: ...10 16 1 Replacement of Pinch Roller and Head Block 37 SA AK250GCP ...
Страница 38: ...10 16 2 Replacement of Motor Capstan Belt A Capstan Belt B and Winding Belt 38 SA AK250GCP ...
Страница 41: ...Note Follow 10 18 Disassembly of cassette lid Step1 to Step 3 Remove the cassette tape 41 SA AK250GCP ...
Страница 44: ...12 4 Checking and Repairing of Power P C B 44 SA AK250GCP ...
Страница 46: ...46 SA AK250GCP ...
Страница 50: ...15 3 Main P C B 50 SA AK250GCP ...
Страница 51: ...15 4 Panel P C B Transformer P C B 15 5 Power P C B 51 SA AK250GCP ...
Страница 52: ...15 6 Waveform Chart 52 SA AK250GCP ...
Страница 54: ...54 SA AK250GCP ...
Страница 62: ...SA AK250GCP 62 ...
Страница 64: ...64 SA AK250GCP ...
Страница 76: ...SA AK250GCP 76 ...
Страница 84: ...SA AK250GCP 84 ...
Страница 89: ...23 Exploded Views 23 1 Cabinet Parts Location SA AK250GCP 89 ...
Страница 90: ...SA AK250GCP 90 ...
Страница 91: ...23 2 Deck Mechanism Parts Location RAA4403 S SA AK250GCP 91 ...
Страница 92: ...23 3 Packaging SA AK250GCP 92 ...