URBAN MULTI

TECHNICAL DATA

Air Conditioning Systems

S-UM4JPQ

URBAN MUL

TI •

 

S-UM4JPQ

 

 

Series T

echnical Data

24-12-2007   12:47:53

S-UM4JPQ.book  Page 1  Monday, December 24, 2007  4:28 PM

Содержание S-UM4JPQ

Страница 1: ...ideas for life URBAN MULTI TECHNICAL DATA Air Conditioning Systems S UM4JPQ ...

Страница 2: ......

Страница 3: ...ifications 5 2 Safety device settings 6 3 Options 7 4 Capacity tables 8 Cooling capacity tables 8 Heating capacity tables 10 5 Dimensional drawing centre of gravity 11 Dimensional drawing 11 Centre of gravity 15 6 Piping diagram 16 7 Wiring diagram 17 Wiring diagram 17 8 Sound data 18 Sound pressure spectrum 18 Sound power spectrum 21 9 Air flow pattern 23 ...

Страница 4: ...7 0 267 0 267 0 357 Nr of Stages 6 6 6 6 8 Empty Tubeplate Hole 4 4 Fin Fin type Cross fin coil Multi louver fins and Hi XSS tubes Fan Type Turbo fan Quantity 1 1 1 1 1 Air Flow Rate Cooling High m min 12 5 12 5 12 5 13 5 15 5 Low m min 9 0 9 0 9 0 9 0 10 0 Heating High m min 12 5 12 5 12 5 13 5 15 0 Low m min 9 0 9 0 9 0 9 0 9 5 Fan Motor Model QTS48D11M Steps 2 2 2 2 2 Output high W 56 56 56 56 ...

Страница 5: ...2 5 16 0 Power Input Cooling kW 0 095 0 120 0 173 0 258 Heating kW 0 114 0 108 0 176 0 246 Casing Material Galvanised steel Dimensions Packing Height mm 220 262 262 304 Width mm 882 882 882 882 Depth mm 882 882 882 882 Unit Height mm 204 246 246 288 Width mm 840 840 840 840 Depth mm 840 840 840 840 Weight Unit kg 21 0 24 0 24 0 26 0 Packed Unit kg 26 0 28 0 28 0 31 0 Dimensions Length Inside mm 2 ...

Страница 6: ... and operation manual Drain hose Washer for hanging bracket Screws Sealing Pads Insulation for fitting Clamp for drain hose Installation guide Drain sealing pad Notes The sound pressure values are mentioned for a unit installed with rear suction The sound power level is an absolute value indicating the power wich a sound source generates Nominal cooling capacities are based on indoor temperature 2...

Страница 7: ... 2 MCA MFA MCA 1 25 x FLA MFA 4 x FLA next lower standard fuse rating minimum 16A select wire size based on the MCA instead of a fuse use a circuit breaker 1 2 ELECTRICAL SPECIFICATIONS S 63UM4JPQ S 80UM4JPQ S 100UM4JPQ S 125UM4JPQ Power Supply Name J Frequency Hz 50 60 Voltage V 220 240 220 Current Minimum circuit amps MCA A 0 9 0 9 1 4 1 9 Maximum fuse amps MFA A 16 16 16 16 Full load amps FLA A...

Страница 8: ... 250V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protector C OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 OFF 108 5 ON 96 15 Drain pump fuse C 145 145 145 145 145 145 145 145 145 3TW28831 3 S 20UM4 S 25UM4 S 32UM4 S 40UM4 S 50UM4 S 63UM4 S 80UM4 S 100UM 125UM4 S ...

Страница 9: ...0 4 Sealing member of air discharge outlet KDBHQ55C140 CZ 06KPU12P S 20UM4 S 25UM4 S 32UM4 S 40UM4 S 50UM4 S 63UM4 S 80UM4 S 100UM4 S 125UM4 S 20UM4 S 25UM4 S 32UM4 S 40UM4 S 50UM4 S 63UM4 S 80UM4 S 100UM4 S 125UM4 H P CZ 02RWU12P CZ 02RT11P CZ 10RSA C CZ 01ANA11P CZ K RP2A52 K RP4AA53 K RP1H98 Z 02ESM11P K JB212AA 01ESW11P 4D057910 The rise of operating sound at with fresh air intake kit Max fres...

Страница 10: ...2 3 1 9 2 6 2 0 2 8 2 1 3 0 2 2 3 1 2 1 3 2 2 1 33 0 1 9 1 7 2 3 1 9 2 6 2 0 2 8 2 1 3 0 2 2 3 1 2 1 3 1 2 0 35 0 1 9 1 7 2 3 1 9 2 6 2 0 2 8 2 1 3 0 2 2 3 0 2 1 3 1 2 0 37 0 1 9 1 7 2 3 1 9 2 6 2 0 2 8 2 1 2 9 2 2 3 0 2 1 3 0 2 0 39 0 1 9 1 7 2 3 1 9 2 6 2 0 2 8 2 1 2 9 2 2 2 9 2 0 3 0 2 0 32 3 6 10 0 2 4 2 3 2 9 2 6 3 4 2 8 3 6 2 8 3 8 2 9 4 3 2 9 4 7 2 9 12 0 2 4 2 3 2 9 2 6 3 4 2 8 3 6 2 8 3 8...

Страница 11: ...6 9 11 2 6 7 20 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 8 6 9 11 1 6 6 21 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 8 6 9 11 0 6 6 23 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 6 6 8 10 8 6 4 25 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 5 6 7 10 7 6 4 27 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 3 6 6 10 5 6 3 29 0 6 1 5 2 7 2 5 8 8 4 6 4 9 0 6 5 9 6 6 7 10 2 6 5 10 4 6 2 31 0 6 1 ...

Страница 12: ... 1 3 1 3 1 3 1 3 0 2 8 5 0 4 1 3 3 3 2 3 2 3 1 3 0 2 8 7 0 6 0 3 4 3 4 3 2 3 1 3 0 2 8 9 0 7 9 3 5 3 4 3 2 3 1 3 0 2 8 11 0 9 8 3 6 3 4 3 2 3 1 3 0 2 8 13 0 11 8 3 6 3 4 3 2 3 1 3 0 2 6 15 0 13 7 3 6 3 4 3 2 3 1 3 0 2 8 32 4 0 19 8 20 0 2 4 2 4 2 3 2 3 2 3 2 3 18 8 19 0 2 4 2 4 2 4 2 4 2 4 2 4 16 7 17 0 2 6 2 6 2 6 2 6 2 6 2 5 14 7 15 0 2 7 2 7 2 7 2 7 2 7 2 7 12 6 13 0 2 9 2 8 2 8 2 8 2 8 2 8 10 ...

Страница 13: ... 5 7 5 7 5 7 5 7 4 7 4 9 5 10 0 7 7 7 7 7 6 7 6 7 6 7 6 8 5 9 1 7 8 7 8 7 8 7 8 7 8 7 8 7 0 7 6 8 1 8 1 8 1 8 1 8 0 8 0 5 0 5 6 8 4 8 4 8 4 8 4 8 4 8 4 3 0 3 7 8 8 8 8 8 7 8 7 8 7 8 7 0 0 0 7 9 3 9 3 9 3 9 3 9 3 8 7 3 0 2 2 9 8 9 8 9 8 9 7 9 4 8 7 5 0 4 1 10 2 10 1 10 0 9 7 9 4 8 7 7 0 6 0 10 5 10 5 10 0 9 7 9 4 8 7 9 0 7 9 10 8 10 6 10 0 9 7 9 4 8 7 11 0 9 8 11 2 10 6 10 0 9 7 9 4 8 7 13 0 11 8 1...

Страница 14: ...he sealing member option the distance of 1500 mm can be reduced to 500 mm on the closed side Please respect the distances as shown on figure above 300 or less S 20 12 32 40 50 63UM4JPQ S 20 50UM4JPQ S 63UM4JPQ 8834 1A 3TW Nr Name Description 1 Liquid pipe connection ø 9 52 flare connection 2 Gas pipe connection ø 15 90 flare connection 3 Drain pipe connection VP25 O D ø32 I D ø25 4 Power supply co...

Страница 15: ... mm Max ceiling opening 910 mm 5 When the conditions exceed 30 C and RH 80 in the ceiling or fresh air is inducted into the ceiling an additional insulation is required polyethylene foam thickness 10 mm or more 6 Please respect the distances as shown above In case a discharge opening is closed with the sealing member option the distance of 1500 mm can be reduced to 500 mm on the closed side 300 or...

Страница 16: ...ly Air flow rate m3 min Ventilation resistance in chamber Note 6 Static pressure of chamber Pa Connecting chamber mounting space 455 Ceiling opening space S 80 100UM4JPQ FXFQ125P 3D057032 Nr Name Description 1 Indoor unit 2 Decoration panel 3 Suction chamber 4 Connecting chamber Right 5 Connecting chamber Left Service acces panel 450x450 mm or more NOTES 1 When installing this kit inspection hatch...

Страница 17: ...drawing 13 5 3D056851 Remote control dimensions Receiver installation procedure Transmitting part Pipe connection side Drain connection side Receiver Decoration panel Remote control holder installation procedure installation to wall surface Receiver detail Liquid crystal remote control wireless Remote control holder S UM4JPQ ...

Страница 18: ...SETTE S UM4JPQ VRF Systems Indoor Units 15 5 Dimensional drawing centre of gravity 5 2 Centre of gravity 5 4TW28839 2 Models A B C D S 20 63UM4JPQ 202 60 409 358 246 90 411 411 288 120 420 420 S UM4JPQ S 80 100UM4JPQ S 125UM4JPQ ...

Страница 19: ...3TW28835 1 Heat exchanger Fan Filter Filter Electronic expansion valve Liquid pipe connection port Gas pipe connection port Refrigerant flow Cooling Heating Refrigerant pipe connection port diameters Model Gas Liquid Ø12 70 Ø6 35 Ø15 90 Ø9 52 S UM4JPQ S 20 25 32 40 50UM4 S 63 80 100 125UM4 ...

Страница 20: ...t orange F1U Fuse T 5A 250V S1L Float switch SS1 Selector switch main sub F2U Field fuse X1M Terminal strip SS2 Selector switch wireless address set HAP Light emitting diode service monitor green X2M Terminal strip Connector for optional parts KPR Magnetic relay M1P Y1E Electronic expansion valve X24A Connector infrared remote control L1 Coil Z1C Ferrite core X33A Connector adapter for wiring M1F ...

Страница 21: ...cale Mode Hi Low A 31 0 28 0 C 37 0 34 0 Drain up Mic position 1 5m 0 3m Hi 49 Note Operation noise differs with operation and ambient conditions S 20UM4JPQ 4D056869 NOTES Over All dB B G N is already rectified Operating conditons Power source 220 240V 50Hz 220V 60Hz Cooling return air temperature 27 C DB 19 C WB outdoor temperature 35 C DB 24 C WB Heating return air temperature 20 C DB 15 C WB ou...

Страница 22: ...C 40 0 42 0 35 0 36 0 Hi Cooling Heating 52 54 Drain up Mic position 1 5m 0 3m Note Operation noise differs with operation and ambient conditions S 63UM4JPQ 4D056873 NOTES Over All dB B G N is already rectified Operating conditons Power source 220 240V 50Hz 220V 60Hz Cooling return air temperature 27 C DB 19 C WB outdoor temperature 35 C DB 24 C WB Heating return air temperature 20 C DB 15 C WB ou...

Страница 23: ...e 35 C DB 24 C WB Heating return air temperature 20 C DB 15 C WB outdoor temperature 7 C DB 6 C WB 4 direction discharge Power level dB Measuring place Anechoic chamber Location of microphone Octave band sound pressure level dB 0dB 0 0002 μ bar Approximate threshold hearing for continuous noise Octave band center frequency Hz Low Hi Scale Mode Hi Low A 44 0 34 0 C 50 0 40 0 Drain up Mic position 1...

Страница 24: ...EC 4 Reference acoustic intensity 0dB 10E 6μ 5 Curve for in cooling mode Sound operation level dB Octave band center frequency Hz W m2 S 32UM4JPQ S 32UM4JPQ 4TW28867 1 NOTES 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dBA A weighted sound operation level A scale according to IEC 4 Reference acoustic intensity 0dB 10E 6μ 2 5 Curve for in cooling mode Sou...

Страница 25: ...4 Reference acoustic intensity 0dB 10E 6μ 2 5 Curve for S 80UM4JPQ in cooling mode Sound operation level dB Octave band center frequency Hz S 80UM4JPQ W m 4TW28907 1 NOTES 1 Data is valid at free field condition 2 Data is valid at nominal operation condition 3 dBA A weighted sound operation level A scale according to IEC 4 Reference acoustic intensity 0dB 10E 6μ 2 5 Curve for S 100UM4JPQ in coolin...

Страница 26: ...ution All round air discharge air flow direction horizontal 2 0m s 1 5m s 1 0m s 0 5m s 22 C 24 C 26 C 20 C 4m 3m 2m 1m 0m 1m 2m 3m 4m S 20UM4JPQ 4D057223 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m 0m 2 7m 2m 1m 0m Cooling air velocity distribution All round air discharge air flow direction horizontal Cooling air temperature distribution All round air discharge air flow direction horizontal 2 0m s 1 5m...

Страница 27: ...ibution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 0m s 1 5m s 1 0m s 0 5m s 26 C 24 C 20 C 22 C S 32UM4JPQ 4D057227 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m 0m 2 7m 2m 1m 0m Cooling air velocity distribution All round air discharge air flow direction horizontal Cooling air temperature distribution All round air discharge air flow direction horizontal 4m 3m 2m ...

Страница 28: ...ution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 0m s 1 5m s 1 0m s 0 5m s 26 C 24 C 22 C 20 C S 50UM4JPQ 4D057231 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m 0m 2 7m 2m 1m 0m Cooling air temperature distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m Cooling air velocity distribution All round air discharge air flow direc...

Страница 29: ...ischarge air flow direction horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0m s 1 5m s 1 0m s 0 5m s 20 C 4m 3m 2m 1m 0m 1m 2m 3m 4m 22 C 24 C 2 C 6 S 80UM4JPQ 4D057235 4m 3m 2m 1m 0m 1m 2m 3m 4m 3m 2m 1m 0m Cooling air velocity distribution All round air discharge air flow direction horizontal Cooling air temperature distribution All round air discharge air flow direction horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0...

Страница 30: ...m 1m 2m 3m 4m 3m 2m 1m 0m Cooling air velocity distribution All round air discharge air flow direction horizontal Cooling air temperature distribution All round air discharge air flow direction horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0m s 1 5m s 1 0m s 0 5m s 20 C 22 C 24 C 26 C 4m 3m 2m 1m 0m 1m 2m 3m 4m S 125UM4JPQ ...

Страница 31: ...rection horizontal Heating air temperature distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m S 20UM4JPQ 4D057222 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m 0m 2 7m 2m 1m 0m Heating air velocity distribution All round air discharge air flow direction horizontal Heating air temperature distribution All round air discharge air flow direction horizontal 2 0m s 1 ...

Страница 32: ...charge air flow direction horizontal 2 0m s 1 5m s 1 0m s 0 5m s 0 25m s 26 C 25 C 27 C 24 C 23 C 22 C 4m 3m 2m 1m 0m 1m 2m 3m 4m 28 C S 32UM4JPQ 4D057226 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m 0m 2 7m 2m 1m 0m Heating air velocity distribution All round air discharge air flow direction horizontal Heating air temperature distribution All round air discharge air flow direction horizontal 4m 3m 2m 1m...

Страница 33: ...ischarge air flow direction horizontal 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 0m s 1 5m s 1 0m s 0 5m s 0 25m s 26 C 24 C 22 C 28 C 23 C 25 C 27 C S 50UM4JPQ 4D057230 4m 3m 2m 1m 0m 1m 2m 3m 4m 2 7m 2m 1m 0m 2 7m 2m 1m 0m Heating air velocity distribution All round air discharge air flow direction horizontal Heating air temperature distribution All round air discharge air flow direction horizontal 4m 3m 2m ...

Страница 34: ...tion horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0m s 1 5m s 1 0m s 0 5m s 0 25m s 28 C 27 C 26 C 25 C 24 C 23 C 22 C 4m 3m 2m 1m 0m 1m 2m 3m 4m S 80UM4JPQ 4D057234 4m 3m 2m 1m 0m 1m 2m 3m 4m 3m 2m 1m 0m Heating air velocity distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0m s ...

Страница 35: ...3m 4m 3m 2m 1m 0m Heating air velocity distribution All round air discharge air flow direction horizontal Heating air velocity distribution All round air discharge air flow direction horizontal 3 2m 3m 2m 1m 0m 3 2m 2 0m s 1 5m s 1 0m s 0 5m s 0 25m s 23 C 25 C 22 C 24 C 26 C 27 C 28 C 4m 3m 2m 1m 0m 1m 2m 3m 4m S 125UM4JPQ ...

Страница 36: ......

Страница 37: ......

Страница 38: ...s RG 12 8FP S UM4JPQ 12 2007 Due to the ongoing innovation of our products the specifications of this catalogue are valid barring typographic errors and may be subject to minor modifications by the manufacturer without prior warning in order to improve the product The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic ...