background image

 
 

Ȗȯ

ȠȘ

ȕȥ

Ȧȟ

ȝ

ǏǕ

ǕǑ

Ǘ

Ǔǔ

Ǥ

POR

TUGUÊS

NEDERLANDS

IT

A

L

IA

N

O

D

E

U

T

S

C

H

E

S

P

A

Ñ

O

L

F

R

A

N

Ç

A

IS

ENGLISH

Air-to-Water Heatpump

■ 

R410A Models

Model No.

Indoor Units

Type Indoor Unit Type

Rated Capacity

80

125

W1

Air-to-Water

S-80MW1E5

S-125MW1E5

ENGLISH

Read through the Installation Instructions before you proceed with the installation. 
In particular, you will need to read under the “IMPORTANT!” section at the top of the page.

FRANÇAIS

Lisez les instructions d’installation avant de commencer l’installation.
En particulier, vous devez lire la section “IMPORTANT!” en haut de la plage.

ESPAÑOL

Lea las Instrucciones de instalación antes de proceder con la instalación del equipo.
En concreto, deberá leer detenidamente la sección “¡IMPORTANTE!” situada al principio de la página.

DEUTSCH

Lesen Sie die Einbauanleitung, bevor Sie mit der Installation beginnen.
Insbesondere die Hinweise im Abschnitt “WICHTIG!” oben auf der Seite müssen unbedingt gelesen werden.

ITALIANO

Leggere le Istruzioni di installazione prima di procedere con l’installazione.
Prestare particolare attenzione alla sezione “IMPORTANTE!” all’inizio della pagina.

NEDERLANDS

Lees de installatie-instructies zorgvuldig door voor u begint met de installatie.
U moet vooral het gedeelte waar “BELANGRIJK!” boven staat heel goed lezen.

PORTUGUÊS

Leia cuidadosamente as instruções de instalação antes de prosseguir com a instalação.
Em particular, é necessário ler as informações na secção “IMPORTANTE!” na parte superior da página.

ǏǕǕǑǗǓǔǤ

ǎǶǭǮȉȀȁDZȁǶǿǙǰdzǯȌDZǿDZǯǷǭȁȉȀȁǭȀdzǿǽǾǶǺȀȂǺDZȅȌȀDZȁDZǹDZȁdzǺDZǯǷǭȁȉȀȁǭȀdzƔ

ǜȂǯǷDZǷǾǶǹȊǺǭƑǴǭȅǾDZǶǭȀȁDZȌǺǭǰǶǭǮȉȀDZȁDZȁdzǺDZǺȏȁdzȁǭƩǜǑǖNjǗǝǓǔǙƘƪȀȁǼǽȉǺȇǹȊǾǼǿȁdzǿȀDZǸȌǰǭǿƔ

ȖȯȠȘȕȥȦȟȝ

ȤəɗɠɎɛɎɛɎɑɖɚɛəɜɓɟɑɑɛɎɐɉɑɖɚɛɉɔɑəɉɖɎɘəɎɍɑɍɉɘəɗɍɣɔɏɑɛɎɚɑɖɚɛɉɔɑəɉɖɎɛɗƔ

ȗɠɉɚɛɖɗɚɛƑɢɎɛəɨɊɋɉɍɉɘəɗɠɎɛɎɛɎəɉɐɍɎɔɉƤȗȕțȢȣƘơɋɌɗəɖɉɛɉɠɉɚɛɖɉɚɛəɉɖɑɟɉɛɉƔ

for Refrigerant R410A

INSTALLATION INSTRUCTIONS

F616843

00_271229_aLL.indb   1

2015-7-28   11:09:14

Содержание S-80MW1E5

Страница 1: ...ncreto deber leer detenidamente la secci n IMPORTANTE situada al principio de la p gina DEUTSCH Lesen Sie die Einbauanleitung bevor Sie mit der Installation beginnen Insbesondere die Hinweise im Absch...

Страница 2: ...ify the wiring of indoor outdoor unit for installation of other components i e heater etc Overloaded wiring or wire connection points may cause electrical shock or fire CAUTION Do not apply excessive...

Страница 3: ...gas Do not add or replace refrigerant other than specified type It may cause product damage burst and injury etc Ventilate the room immediately in the event that is refrigerant gas leaks during the in...

Страница 4: ...rigerant charge of the product see unit name plate 2 Additional refrigerant amount charged in the field 3 Total refrigerant charge 4 Contains fluorinated greenhouse gases covered by the Kyoto Protocol...

Страница 5: ...d Hose Installation 4 ELECTRICAL WIRING 11 4 1 General Precautions on Wiring 4 2 Recommended Wire Length and Wire Diameter for Power Supply System 4 3 Wiring System Diagram For stranded wiring Example...

Страница 6: ...ch 6 Pressure gauge 7 Water pump 8 1 phase RCCB ELCB 9 Cabinet front plate 10 Cabinet 11 Handle 2 pieces 12 Overload protector 3 pieces 13 Expansion vessel 14 Heater assembly 15 Bushing 16 Air purge v...

Страница 7: ...mable Type REV200 1 5 Type of Copper Tube and Insulation Material If you wish to purchase these materials separately from a local source you will need 1 Deoxidized annealed copper tube for refrigerant...

Страница 8: ...pport a load that is four times the indoor unit weight select a location where tubing and drain pipe have the shortest run to the outdoor unit allow room for operation and maintenance as well as unres...

Страница 9: ...hing for tube Assembly Putty or caulking compound Sleeve for tube assembly 70 mm through hole 3 4 Indoor Unit Installation Installation plate a Slots Hooks Wall Indoor unit back Installation plate c S...

Страница 10: ...indoor unit Total amount of water in system should be below 200 L Note This amount of water does not include the tank unit volume If total amount of water is over 200 L please add expansion vessel fi...

Страница 11: ...changes in the internal wiring can be very dangerous The manufacturer will accept no responsibility for any damage or misoperation that occurs as a result of such unauthorized changes 7 Regulations o...

Страница 12: ...t WARNING This equipment must be properly earthed U2 U1 U1 U2 R2 R1 L N R2 R1 R2 R1 R2 R1 2 1 2 1 U2 U1 L N U2 U1 L N U2 U1 L N 2 1 2 1 2 1 C B A L N L N L N L N 2 1 A A A B C B 2 1 L1 L2 L3 N 2 1 L1...

Страница 13: ...or unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Indoor unit Outdoor unit Branch point More than 2 m required 5 Use shielded wires for inter unit control wiring B and ground the shi...

Страница 14: ...insulated in Step 2 Stranded wire Ring pressure terminal Screw and Special washer Ring pressure terminal Terminal board Ring pressure terminal Screw Special washer Wire Wire Strip 10 mm Insulation ta...

Страница 15: ...ot to attach the oil to the surface of screw This is effective for reducing gas leaks 3 For proper connection align the union tube and flare tube straight with each other then screw in the flare nut l...

Страница 16: ...leakage In order to prevent damage to the flare caused by over tightening of the flare nuts use the table above as a guide when tightening When tightening the flare nut on the liquid tube use an adju...

Страница 17: ...terminal Malfunction may occur Do not bundle together with the power source wiring or store in the same metal tube Operation error may occur If noise is induced to the unit power supply attach a nois...

Страница 18: ...in the correct direction Top case Back side Wood screw supplied Hole for screw Mount the bottom case to the wall Clamper supplied Pass through the hole 2 2 Embedded type Preparation Make 2 holes for...

Страница 19: ...late towards you to remove the front plate from left and right hooks 3 Hold the left edge and right edge of front plate to lift up front plate from hooks Hook Lift up Screws Fix the left and right hoo...

Страница 20: ...nstantly press the or button Select 13 Air to Water unit on the LCD display and press the button 0DLQWHQDQFH IXQF 6HW HOHF FRQVXPSWLRQ 6HW WRXFK NH KHFN WRXFK NH 6HO 3DJH RQILUP 7 8 LU WR DWHU XQLW ST...

Страница 21: ...ress the button 6HW LU WR DWHU XQLW 7 8 6HW SXPS VSHHG LU WR DWHU XQLW 3XPS VSHHG 7 8 RQILUP 6HO LU WR DWHU XQLW LU SXUJH DQFHO LQW KHDWHU DODUP LU WR DWHU VHWWLQJV 6HO 6HW 7 8 3XPS VSHHG VHWXS The de...

Страница 22: ...thermo sensor use 0000 No 0001 R C 0002 Remote sensor 0003 Ext thermo c 07 2 way Valve 0000 Normal Open 0001 Normal Close c 22 Outdoor temperature using internal heater 20 C 25 C 0 C c c 31 Temperatu...

Страница 23: ...oller perform the following steps How to Service Overload Protector Perform the steps in 7 2 How to Remove Side Cabinet before performing the steps below 1 Remove these 3 screws 2 Push control board a...

Страница 24: ...nly be done when power is supplied to the Indoor Unit WARNING Be careful not to touch parts other than RCCB ELCB test button when the power is supplied to Indoor Unit Else electrical shock may happen...

Страница 25: ...clogged with dust or obstacles Remove dust or obstruction Improper temperature settings Refer to Tips for Energy Saving Room is exposed to direct sunlight in cooling mode Doors and or windows are open...

Отзывы: