Panasonic S-45MK1E5A Скачать руководство пользователя страница 5

5

TIMER

OPERATION

STANDBY

Air intake

Air outlet

Receiver

Emergency Operation button

E

NGLISH

Names of Parts 

Operation Mechanism

 Heating performance

 

Since this air conditioner utilizes outside air for heating, 

its heating performance deteriorates as outside tempera-

ture decreases.

(Due to heat pump system)

In that case, use another heating appliance.

 Defrosting

 

This appliance may start defrosting operation to melt 

frost formed in the outdoor unit.

1

Defrosting starts

: The indoor unit fan stops (or the 

speed becomes extremely slow).

”  ” (STANDBY) appears.

2

Heating operation resumes after several 

minutes

: The indoor unit fan remains stopped (or 

it will run at a very slow speed) until the indoor heat 

exchanger coil warms up suf

fi

 ciently.

 ” ” (STANDBY) is shown.

3

 

Defrosting is complete

: The indoor unit fan starts 

operation.

 ”  ” (STANDBY) disappears.

INDOOR UNIT

 ‘‘DRY’’ operation

 

Once the room temperature reaches the level that was 

set, the outdoor unit repeats the cycle of turning on and 

off automatically.

 

When the outdoor unit is turned off, the indoor unit fan 

will stop, too.

(To prevent the humidity in the room from rising again)

 

When the room temperature is more likely to reach the 

level that was set, the fan speed is set to ‘‘breeze’’ (light 

wind) automatically.

 

‘‘DRY’’ operation is not possible if the outdoor tempera-

ture is 15 °C or less.

 Should the power failure occurs while the 

unit is running

When the unit automatically resumes operation after 

temporary power failure, it uses the same settings before 

the power was cut off.

Optional

Model No.

CZ-RWSK2 (K1 type)

Wireless Remote Controller

Model No.

CZ-RTC2

For all indoor 

units

Timer Remote Controller

Read the operating instructions included with the Remote Controller.

Model No.

CZ-RTC3

For all indoor 

units

High-Spec Wired Remote Controller

OI̲00̲284010̲EU̲all.indb   5

OI̲00̲284010̲EU̲all.indb   5

2013/11/29   14:35:31

2013/11/29   14:35:31

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание S-45MK1E5A

Страница 1: ...ur toute r f rence ult rieure ESPA OL 18 25 Antes de operar la unidad lea atentamente estas instrucciones de funcionamiento y gu rdelas para futuras consultas DEUTSCH 26 33 Bevor Sie das Ger t in Betr...

Страница 2: ...erant gas leakage may cause fire For safety be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing Pull off the power plug from a receptacle or switch of...

Страница 3: ...fied cord joint cord extension cord or unspecified cord to prevent overheating and fire Stop using the product when any abnormality failure occurs and disconnect the power plug or turn off the power s...

Страница 4: ...DBT Heating 15 C 30 C DBT 20 C 18 C WBT Cooling Heating 10 C 24 C DBT DBT Dry bulb temperature WBT Wet bulb temperature Information for Users on Collection and Disposal of Old Equipment and Used Batte...

Страница 5: ...room temperature reaches the level that was set the outdoor unit repeats the cycle of turning on and off automatically When the outdoor unit is turned off the indoor unit fan will stop too To prevent...

Страница 6: ...may drip on to the floor HEAT COOL DRY FAN Airflow direction display Airflow direction display FLAP button FLAP button Fan and heating Cooling and drying 5 levels 3 levels Recommended Recommended Fixe...

Страница 7: ...P 8 To prevent conditioned air from escaping keep win dows doors and any other openings closed Adjusting airflow direction for multiple indoor units Timer remote controller only When setting the airf...

Страница 8: ...en tripped consult your dealer without turning it on Fuse blow out Contact your dealer Poor cooling or heating performance The air intake or air outlet of indoor and outdoor units is clogged with dust...

Страница 9: ...direction Airflow direction changes while operating Airflow direction cannot be set Airflow direction cannot be changed When air discharge temperature is low during heating operation or during defrost...

Страница 10: ...09285010 DC1113 0 Authorised representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany OI 00 284010 EU all indb 102 OI 00 284010 EU all indb 1...

Отзывы: