Installation Location

We recommend that this air conditioner be installed properly by qualified 
installation technicians in accordance with the Installation Instructions 
provided with the unit.

Before installation, check that the voltage of the electric supply in your home or office 
is the same as the voltage shown on the nameplate.

Electrical Requirements

1.

All wiring must conform to the local electrical codes. Consult your dealer or a 
qualified electrician for details.

2.

Each unit must be properly grounded with a ground (or earth) wire or through the 
supply wiring.

3.

Wiring must be done by a qualified electrician.

Safety Instructions

Read this Instruction Manual carefully before using this air conditioner. If you 
still have any difficulties or problems, consult your dealer for help.

This air conditioner is designed to give you comfortable room conditions. Use 
this only for its intended purpose as described in this Instruction Manual.

Do not install this air conditioner where there are fumes or flammable gases, 
or in an extremely humid space such as a greenhouse.

Do not install the air conditioner where excessively high heat-generating 
objects are placed.

Avoid:

To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit 
where salty sea water can splash directly onto it or in sulphurous air near a spa.

To warm up the system, the power mains must be 
turned on at least five (5) hours before operation. 
Leave the power mains ON unless you will not be 
using this appliance for an extended period.

Never touch the unit with wet hands.

Never use or store gasoline or other flammable vapor or liquid near the air 
conditioner — it is very dangerous.

This air conditioner has no ventilator for intaking fresh air from outdoors. 
You must open doors or windows frequently when you use gas or oil 
heating appliances in the same room, which consume a lot of oxygen from 
the air. Otherwise there is a risk of suffocation in an extreme case.

Provide a power outlet to be used exclusively for each unit, and a power 
supply disconnect, circuit breaker and earth leakage breaker for 
overcurrent protection should be provided in the exclusive line.

Provide a power outlet exclusively for each unit, and full disconnection 
means having a contact separation in all poles must be incorporated in the 
fixed wiring in accordance with the wiring rules.

To prevent possible hazards from insulation failure, the unit must be 
grounded.

Do not clean inside the indoor and outdoor units by users. Engage 
authorized dealer or specialist for cleaning.

In case of malfunction of this appliance, do not repair by yourself. Contact 
to the sales dealer or service dealer for a repair.

Refrigerant gas leakage may cause fire.

For safety, be sure to turn the air conditioner off and also to 
disconnect the power before cleaning or servicing.

Stop using the product when any abnormality/failure occurs and 
disconnect the power plug or turn off the power switch and breaker. (Risk of 
smoke/fire/electric shock)

CAUTION

Power mains

ON

OI-100-3-EN

01_85464609100010_EN.fm  Page 3  Friday, February 4, 2011  3:22 PM

Содержание S-200PE1E8

Страница 1: ...uct High Static Pressure S 200PE1E8 S 250PE1E8 Outdoor Unit Heat Pump Unit 3 phase U 200PE1E8 U 250PE1E8 Split System Air Conditioner Climatiseur Split System Split System Klimagerät Condizionatore d Aria Split Aparelho de Ar Condicionado Sistema Split Κλι ατιστικ Δύο Μονάδων Acondicionador de Aire de tipo Sistema Partido INSTRUCTION MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG ISTRUZIONI PER L USO MA...

Страница 2: ...lems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate on the bottom of the cabinet Model No ______________________ Serial No ____________________ Date of purchase ________________________________________________ Dealer s address ________________________________________________ Phone number ________________ Alert Symb...

Страница 3: ... 5 hours before operation Leave the power mains ON unless you will not be using this appliance for an extended period Never touch the unit with wet hands Never use or store gasoline or other flammable vapor or liquid near the air conditioner it is very dangerous This air conditioner has no ventilator for intaking fresh air from outdoors You must open doors or windows frequently when you use gas or...

Страница 4: ...ppliance by a person responsible for their safety Children should be supervised to ensure that do not play with the appliance Do not cool or heat the room too much if babies or invalids are present Do not sit or step on the unit You may fall down accidentally Do not stick any object into the FAN CASE You may be injured and the unit may be damaged The compressor may occasionally stop during thunder...

Страница 5: ...ing mode to 30 C DBT Outdoor temperature range Cooling mode 15 C 43 C DBT Heating mode 20 C 15 C WBT DBT Dry bulb temperature WBT Wet bulb temperature Refer to the Instruction Manual attached to the optional Wireless Remote Control Unit Refer to the Instruction Manual attached to the optional Timer Remote Control Unit NOTE Wireless type available for all indoor units NOTE Wired type available for ...

Страница 6: ... in some cases and the STANDBY indicator appears on the display until defrosting is completed Heating operation then restarts after several minutes This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms standby on the display For several minutes after the start of heating operation the indoor fan will not start running or it will run at very low sp...

Страница 7: ... brush or wipe them with a clean soft cloth If these parts are stained use a clean cloth moistened with water When cleaning the air outlet side be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning the indoor unit Do not wipe plastic parts using very hot water 2 Some metal edges and the fins are sharp and may cause injury if handled improperly be espe...

Страница 8: ... improve the airflow 2 Heat source or many people in room 2 Eliminate heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat or cold out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is set too high for cooling or too low for heating 5 Set the temperature lower or higher 6 Defrosting system does not work 6 Consult you...

Страница 9: ...batteries correctly you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling For more information about collection and recycling of old products and batteries please contact your local municipality your waste disposal service or the point of sale where you purchased the item...

Страница 10: ...8 Hi 47 Me 46 Lo Sound Power Level dB A 71 Unit Dimensions H W D mm 1526 940 340 467 1428 1230 Net Weight kg 118 110 Model Name Outdoor Unit Indoor Unit U 250PE1E8 S 250PE1E8 Power Source 380 400 415 V 3 phase 50 60 Hz 220 230 240 V single phase 50 60 Hz Cooling Capacity kW 25 0 6 0 28 0 BTU h 85 300 20 500 95 500 Heating Capacity kW 28 0 6 0 31 5 BTU h 95 500 20 500 107 500 Sound Pressure Level d...

Страница 11: ...Authorized representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg Germany Printed in Japan ...

Отзывы: