Panasonic S-180PE3R5B Скачать руководство пользователя страница 2

2

 

z

Safety Precautions

 ........................................................... 2

 

z

Precautions for Use

 ......................................................... 5

 

z

Names of Parts

 ................................................................. 6

 

z

Operation

 .......................................................................... 6

 

z

Maintenance

 ..................................................................... 7

• 

Operation Mechanism

 ................................................... 7

 

z

Troubleshooting

 ............................................................... 8

• 

Before Requesting Services

 ......................................... 9

 

z

Specifications

 ................................................................. 10

• 

Indoor unit

 .................................................................... 10

Contents

Thank you for purchasing this Panasonic product.

This product is a commercial air conditioner indoor unit.

Installation Instructions attached.

Product Information

If you have problems or questions concerning your Air 

Conditioner, you will need the following information. Model and 

serial numbers are on the nameplate.

Model No. 

Serial No. 

Date of purchase

Dealer’s address

Phone number

Safety Precautions

The following symbols used in this manual, alert you to 

potentially dangerous conditions to users, service personnel or 

the appliance:

WARNING

This symbol refers to a hazard or 

unsafe practice which can result in 

severe personal injury or death.

CAUTION

This symbol refers to a hazard or 

unsafe practice which can result 

in personal injury or product or 

property damage.

Prohibited matters

Matters to be  

observed

• 

Read these Operating Instructions carefully before using this 

air conditioner. If you still have any difficulties or problems, 

consult your dealer for help.

• 

This air conditioner is designed to give you comfortable 

room conditions. Use this only for its intended purpose as 

described in these Operating Instructions.

Confirm to authorized dealer 

or specialist on usage of 

specified refrigerant type. Using 

of refrigerant other than the 

specified type may cause product 

damage, burst and injury etc.
This air conditioner has no 

ventilator for intaking fresh air 

from outdoors. You must open 

doors or windows frequently 

when you use gas or oil heating 

appliances in the same room, 

which consume a lot of oxygen 

from the air. 

Otherwise there is a risk of 

suffocation in an extreme case.
Never use or store gasoline or 

other flammable vapor or liquid 

near the air conditioner — it is 

very dangerous.
Do not use this appliance in a 

potentially explosive atmosphere.
Never touch the unit with wet 

hands.

Do not insert your fingers or 

other objects into the air 

conditioner indoor or 

outdoor unit, rotating parts may 

cause injury.

WARNING

WARNING

This symbol shows that this equipment 
uses a flammable refrigerant. If the 
refrigerant is leaked, together with 
an external ignition source, there is a 
possibility of ignition.

CAUTION

This symbol shows type of flammable 
refrigerant contained in the system.

CAUTION

This symbol shows that a service 
personnel should be handling this 
equipment with reference to the 
Technical Manual.

CAUTION

This symbol shows that there is 
information included in the Operating 
Instructions and/or Installation Instructions.

Important Information Regarding The  

Refrigerant Used

NOTE

Refer to the Installation Instructions attached to the 

outdoor unit.

OI_00_310270_Eng.indb   2

2018/12/5   13:11:22

Содержание S-180PE3R5B

Страница 1: ...S 180PE3R5B S 200PE3R5B S 224PE3R5B High Static Pressure Ducted Type E3 ACXF55 23430 OUTDOOR UNIT Single Split 3 phase Refrigerant type R410A R32 Type PE2 U 180PE2R8A U 200PE2R8A U 224PE2R8A Type PZH2...

Страница 2: ...in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and...

Страница 3: ...s must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint cord...

Страница 4: ...or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to en...

Страница 5: ...arm up z z Leave the power mains ON for continuous use ON NOTE Pull off the power plug from a receptacle or switch off the breaker or switch off the power disconnecting mean to isolate the air conditi...

Страница 6: ...ded with the Remote Controller High spec Wired Remote Controller Optional Model No CZ RWS3 Infrared Remote Controller The receiver Model No CZ RWRC3 Air intake side duct flange rear Electrical compone...

Страница 7: ...the room from rising again z z When the room temperature is more likely to reach the level that was set the fan speed is set to breeze light wind automatically Should the power failure occurs while t...

Страница 8: ...rge amounts of oil mist exist cleaning is necessary because the unit inside heat exchanger is dirty Contact your dealer Fog occurs during heating operation Defrost operation is in process The fan is r...

Страница 9: ...t sunlight in cooling mode Doors or windows are open Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode Lower th...

Страница 10: ...5 0 BTU h 68 200 76 400 85 300 Sound pressure level High dB A 46 46 47 Medium dB A 44 44 45 Low dB A 41 41 42 Sound power level High dB A 78 78 79 Medium dB A 76 76 77 Low dB A 73 73 74 Unit dimension...

Страница 11: ...11 MEMO OI_00_310270_Eng indb 11 2018 12 5 13 11 24...

Страница 12: ...Printed in Malaysia Panasonic Corporation 2018 ACXF55 23430 DC1218 0 Panasonic Corporation http www panasonic com OI_00_310270_Eng indb 12 2018 12 5 13 11 24...