VRVII and VRVII-S system air conditioner
4PW35761-1A

 

 

 

Operation manual

 

3

 

2.

I

 

MPORTANT

 

 

 

INFORMATION

 

 

 

REGARDING

 

 

 

THE

 

 

 

REFRIGERANT

 

 

 

USED

 

This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.

Refrigerant type:

R410A

GWP

 

(1)

 

 value:

1975

 

(1)

 

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required
depending on European or local legislation. Please contact your local
dealer for more information.

 

3.

W

 

HAT

 

 

 

TO

 

 

 

DO

 

 

 

BEFORE

 

 

 

OPERATION

 

This operation manual is for the following systems with standard
control. Before initiating operation, contact your dealer for the
operation that corresponds to your system type and mark.

If your installation has a customized control system, ask your dealer
for the operation that corresponds to your system.

Outdoor units 

(See figure 1)

Names and functions of parts 

(See figure 1)

(

figure 1

 shows systems with changeover remote control switches.)

 

4.

R

 

EMOTE

 

 

 

CONTROLLER

 

Refer to the operation manual of the remote controller.

 

5.

C

 

HANGEOVER

 

 

 

SWITCH

 

: N

 

AME

 

 

 

AND

 

 

 

FUNCTION

 

 

 

OF

 

 

 

EACH

 

 

 

SWITCH

 

 

 

(See figure 2)

 

1

 

FAN ONLY/AIR CONDITIONING SELECTOR SWITCH

Set the switch to 

 

 

 

for fan only operation or to 

 for heating or

cooling operation.

 

2

 

COOL/HEAT CHANGEOVER SWITCH

Set the switch to 

 

 

 

for cooling or to 

 for heating operation.

 

6.

O

 

PERATION

 

 

 

RANGE

 

Operation range

 

Use the system in the following temperature and humidity ranges for
safe and effective operation.

 

7.

O

 

PERATION

 

 

 

PROCEDURE

 

 

Operation procedure varies according to the combination of
outdoor unit and remote controller. Read 

"3. What to do before

operation" on page 3

.

 

 

To protect the unit, turn on the main power switch 6 hours before
operation.

 

 

If the main power supply is turned off during operation, operation
will restart automatically after the power turns back on again.

 

7.1.

Cooling, heating, fan only, and automatic 
operation 

 

(See 

figure 3

 and 

figure 4.1

)

 

 

Changeover cannot be made with a remote controller whose
display shows 

 (change-over under centralized control).

 

 

When the display 

 (change-over under centralized control)

flashes, refer to 

"7.4. Setting the master remote controller" on

page 5

.

 

 

Automatic operation can be selected only for REYQ series.

 

 

RXQ series let you select fan only and cooling operation.

 

 

The fan may keep on running for about 1 minute after the
heating operation stops.

 

 

The air flow rate may adjust itself depending on the room
temperature or the fan may stop immediately. This is not a
malfunction.

 

Cool/heat 

changeover 

remote control 

switch

operation modes

 

Cooling only 

 

RXQ

 

 series

Heat pumps 

 

RXYQ

 

 series

 

 

 yes

 

 

 no

Heat pumps 

 

RXYSQ

 

 series

 

 

 yes

 

 

 no

 

Heat recovery series

 

Heat pumps 

 

REYQ

 

 series

 

 

 yes

 

 

 no

 

1

 

Outdoor unit

 

2

 

Indoor unit

 

3

 

Remote controller

 

4

Inlet air

5

Outlet air

6

BS (branch selector) unit

7

Cool/heat changeover remote control switch

RXQ5~10

RXYQ5~16 + REYQ8~16

COOLING

COOLING

HEATING

Outdoor temperature

–5~43°C DB

–5~43°C DB

–20~21°C DB

–20~15.5°C WB

Indoor temperature

21~32°C DB

21~32°C DB

15~27°C DB

14~25°C WB

14~25°C WB

Indoor humidity

80%

(*)

80%

(*)

RXYSQ4~6

COOLING

HEATING

Outdoor temperature

–5~46°C DB

–20~24°C DB

(†)

(†) Range for operation: –20~–15°C WB. Range for continuous operation: 

–15~15.5°C WB.

–20~15.5°C WB

Indoor temperature

21~32°C DB

15~27°C DB

14~25°C WB

Indoor humidity

80%

(*)

(*)

to avoid condensation and water dripping out the unit.
If the temperature or the humidity is beyond these conditions, safety devices may 
work and the air conditioner may not operate.

Содержание RXQ5M9W1B

Страница 1: ...M9W1B RXQ8M9W1B RXQ10M9W1B RXYQ5M9W1B RXYQ8M9W1B RXYQ10M9W1B RXYQ12M9W1B RXYQ14M9W1B RXYQ16M9W1B RXYSQ4M7V3B RXYSQ5M7V3B RXYSQ6M7V3B REYQ8M8W1B REYQ10M8W1B REYQ12M8W1BA REYQ14M8W1BA REYQ16M8W1BA and S...

Страница 2: ...2 3 1 1 4 3 2 3 1 3 1 2 1 1 5 3 5 2 4 6 UNIT NO 1 2 3 4 2 1 2 7 Ceiling Suspended Wall Mounted Double flow Multi flow Corner 8 RXYSQ RXYQ 1 1 4 4 3 2 6 7 5 5 REYQ 1 RXYSQ RXYQ 1 5 5 4 3 2 4 7 1 5 5 4...

Страница 3: ...ensure proper use of the equipment Be sure to follow these important safety cautions WARNING It is not good for your health to expose your body to the air flow for a long time In order to avoid electr...

Страница 4: ...mplete combustion or deformation of the unit due to the heat Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury CAUTION Never...

Страница 5: ...ge 3 To protect the unit turn on the main power switch 6 hours before operation If the main power supply is turned off during operation operation will restart automatically after the power turns back...

Страница 6: ...off button The operation lamp lights up and the system starts operation Press the air flow direction adjust button Only for Double flow Multi flow Corner Ceiling suspended and Wall mounted Refer to 7...

Страница 7: ...mote controllers control one indoor unit in case of group control system one group of indoor units The unit is individually operated 8 ENERGY SAVING AND OPTIMUM OPERATION Observe the following precaut...

Страница 8: ...n operation is possible but cooling and heating do not work Immediately after the power is turned on The micro computer is getting ready to operate Wait 10 minutes Symptom 4 The fan strength does not...

Страница 9: ...Stop the operation The operation switch does not work well Measure Turn off the power If the display the unit number and the operation lamp flash and the malfunction code appears See figure 6 Measure...

Страница 10: ...conditioning Recommended replacement cycle of wear parts Table 2 Replacement Cycle list Contact your dealer for details Moving and discarding the unit Contact your dealer for removing and reinstallin...

Страница 11: ...NOTES NOTES...

Страница 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW35761 1A...

Отзывы: