Panasonic RG-R811A Скачать руководство пользователя страница 11

Maintenance of unit

1

3

2

Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with a clean
cloth. Reinstall grille after finishing.

NOTE: The grille should be dry after cleaning. 

3

2

1

Clean grille. (Don’t put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth).  

Remove dust and dirt from fan body using a vacuum cleaner.  

Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product is 
designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts, call 
Panasonic Call Center at 1-866-292-7299 (USA). 

Properly insulate the area around the fan to minimize 
building heat loss and gain. Loose fill or batt insulation
can be placed directly over the fan housing in the 
attic. Panasonic fans do not create excessive heat 
which is a common problem with recessed light 
fixtures and some competitor’s fan/light combination. 
Our efficient, cool-running motors do not create 
enough ambient heat to be subjected to these 
limitations. The ducting from this fan to the outside of 
the building has a strong effect on the air flow, noise 
and energy use of the fan. Use the shortest, straightest
duct routing possible for best performance, and avoid 
installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss 
and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.   

4 inches or 3 inches roof jack, wall cap,
or soffit vent with backdraft damper

Mechanically connect duct to termination
and seal with mastic or approved foil 
faced tape

2-3 ft straight run before elbow

In attic installation, 
caulk box to drywall 

Short piece of flexible duct helps
alignment and absorbs sound. 
Clamps plus mastic or approved
foil faced tape at all flex joints

Insulation

Foil tape tightly covers all metal
duct joints (glue PVC joints)

Drywall

Vacuum cleaner

Drywall

Gloves

11

MAINTENANCE (CLEANING) CONTINUED

PRACTICAL GUIDE TO INSTALLATION

SPECIFICATIONS

PRODUCT SERVICE

RG-R811A

1.1

11.6

 1043

9.5(4.3)

80

0.4

905

7.1

60

4

120

110

Exhaust

Model No. 

Air

direction

Voltage

(V)

Frequency

(Hz)

Noise

(sones)

Duct

diameter

(inches)

Speed

(rpm)

Air volume

at 0.1” WG

(CFM)

Power

(W)

Weight
lb. (k  )

Содержание RG-R811A

Страница 1: ... of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions WARNING CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury Denotes a hazard that could result in property damage The following symbols are used to classify and describe the type of instructions t...

Страница 2: ...roper combustion and exhausting of gases through the flue chimney of fuel Ducted exhaust fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit These models are UL listed for tub and shower enclosures If this product is no l...

Страница 3: ...cted to one switch in parallel the units may not function Do not install the unit where ducts are configured as shown in below Bend close to duct adaptor Squeezed duct Successive bending Excessive bending Adaptor These products use a sirocco fan driven by a DC motor powered by an integral transformer The motor is designed to have long operating life high dynamic response higher speed ranges and en...

Страница 4: ...me Grille Blade Junction box Adaptor PCB box Pick A Flow switch Part name No No Fan body Damper Flex Z Fast bracket 5 7 8 9 10 1 4 2 3 Duct reducer optional part 6 4 SUPPLIED ACCESORIES DIMENSIONS 1 2 3 4 6 5 5 5 8 140 12 1 8 307 3 7 8 96 7 10 13 330 5 5 8 143 10 3 4 271 2 3 4 69 7 9 8 2 7 8 71 4 1 3 8 32 6 1 1 2 37 10 3 8 263 5 1 4 133 13 330 7 ...

Страница 5: ...option CFM 80 110 80 CFM Factory setting Pick A Flow Feature This product comes with Pick A Flow speed options The Pick A Flow switch on the face of the product allows the option to choose 80 or 110 CFM This product can run continuously or intermittently depending upon the needs of the owner Pick A Flow switch Fan body Main control circuit DC motor Black White Green Junction box Power switch Live ...

Страница 6: ...ll cause the product to work inefficiently and create a loud noise If you require use of the 3 inch duct reducer optional accessory use the following method Insert Duct tape Adaptor Damper Tape Disconnect power supply before installing the unit Please wear gloves to protect hands during the installation WARNING Joist 2 Tapping screws ST4 2X20 Flex Z Fast bracket Align 3 3 Joist Flex Z Fast bracket...

Страница 7: ...ock out hole Joist 2 1 Remove screw from junction box cover to remove the knock out hole and secure conduit or stress relief to junction box knock out hole Install the circular exhaust duct and secure it with clamps or ties and seal it with mastic or approved foil tape A 3 or 4 inch circular duct is needed to connect to the relevant part of the adaptor Earth ground AC 120 V 60 Hz Power supply Whit...

Страница 8: ...he machine screw Step 6 to avoid cross threading and to ensure that the screw does not strip or come in contact with the Flex Z Fast bracket CAUTION Insert fan body Insert fan body and slide into adaptor assembly using the guide parts until you hear a click from the hook 1 Joist Guide parts Guide parts 1 Joist 8 2 A Flange Drywall Joist Plug connector Receptacle Machine screw M4X8 1 2 Self drillin...

Страница 9: ...r duct is needed to connect to the relevant part of the adaptor Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Connect wires Refer to WIRING DIAGRAM Page 5 Follow all the local electrical safety codes as well as the National Electrical Code NEC Use UL approved wire nuts to connect fan wires After connecting wires replace junction box cover 1 IMPORTANT Remove the tape pl...

Страница 10: ...e Mounting spring Remove grille by pulling down one mounting spring then pull the other Insert fan body Assembled view detail Hook Guide parts Guide parts 1 Joist 1 2 Plug connector into receptacle and secure fan body to adaptor by using the machine screw M4X8 When the flange overlaps Flex Z Fast bracket secure it by using 2 self drilling screws Follow the step 7 to 8 in INSTALLATION RETROFIT 3 In...

Страница 11: ...subjected to these limitations The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing duc...

Страница 12: ...n how long an implied warranty lasts so the above exclusions or limitation may not apply to you Obtain Product Information and Operating Assistance locate your nearest distributor or make Customer Service and Literature requests by visiting our Web Site at us panasonic com ventfans or send your request by E mail to ventfans us panasonic com You may also contact us directly at 1 866 292 7299 Monday...

Отзывы: