3. Using the remote control, set the brightness, contranst, color and
tint to normal position.
4. Activate the adjustment mode display of
Fig. 1-1
and press the
channel button (15) on the remote control to select "COLOR".
5. Adjust the VOLTS RANGE VARIABLE knob of the oscilloscope
until the range between white 100% and 0% is set to 4 scales on
the screen of the oscilloscope.
6. Press the VOL. UP/DOWN button on the remote control until the
red color level is adjusted to 120 ±10% of the white level. (Refer to
Fig. 2-3
)
7. Receive the color bar pattern. (Audio Video Input)
8. Press the INPUT button on the remote control to set to the AV
mode. Then perform the above adjustments 2~6.
Fig. 2-3
13.2.11. SUB CONTRAST
1. Activate the adjustment mode display of
Fig. 1-1
and press the
channel button (14) on the remote control to select "CONTRAST".
2. Press the VOL. UP/DOWN button on the remote control until the
contrast step No. becomes "96".
3. Receive a broadcast and check if the picture is normal.
4. Press the INPUT button on the remote control to set to the AV
mode. Then perform the above adjustments 1~3.
13.2.12. HORIZONTAL PHASE
1. Receive the monoscope pattern.
2. Activate the adjustment mode display of
Fig. 1-1
and press the
50