8.1 Main Items that can be Communicated through I/O Interface
PV500 is provided with I/O interfaces as below.
•
I/O connector (MIL connector type)
Input: 32 pins, Output: 32 pins
•
I/O terminal block
Input: 14 pins, Output: 15 pins
Input
The operations shown in the table below can be executed by input from the external devices.
Connector
Terminal Block
Command*
3
Execute inspection
STA0-3
STA0
%S
Execute reinspection
ASN0-5*
1
ASN0-2*
2
%R
Execute type switch
TYPE+IN0-7
TYPE+IN0-7
%X
Set template
RENT+IN0-15
ASN0-2*
2
+IN0-7
%A
Switch layout
DISP+IN0-4
DISP+IN0-4
%I
Switch between RUN/STOP
RUN/STOP
ASN0-2*
2
%RM
Reset statistics data
ASN0-5*
1
ASN0-2*
2
%Q
Reset error signal
ASN0-5*
1
ASN0-2*
2
%E
Save setting data
Storage Space in PV500
ASN0-5*
1
+IN0-6
ASN0-2*
2
+IN0-6
%MW
SD memory card
ASN0-5*
1
+IN0-6
ASN0-2*
2
+IN0-6
%CW
Read setting data
Storage Space in PV500
ASN0-5*
1
+IN0-6
ASN0-2*
2
+IN0-6
%MR
SD memory card
ASN0-5*
1
+IN0-6
ASN0-2*
2
+IN0-6
%CR
Operate image
memory of PV
Save in a SD memory card
(backup)
ASN0-5*
1
ASN0-2*
2
%SS
Delete
ASN0-5*
1
ASN0-2*
2
%SR
Print screen
ASN0-5*
1
ASN0-2*
2
%PS
Save the latest inspection image in a SD memory
card or PC etc. through Ethernet
ASN0-5*
1
ASN0-2*
2
---
Abort inspection/process
ASN0-5*
1
ASN0-2*
2
%CC
Abort Save/read Setting Data
ASN0-5*
1
ASN0-2*
2
%CD
*1: Up to six functions are available because six points of ASN0 to 5 are assigned functions. ASN0 to 2 are
common function with I/O terminal block.
*2: Up to three functions are available because three points of ASN0 to 2 are assigned functions. They are
common functions with ASN0 to 2 of I/O connector.
*3: Command to control with interface of RS-232C and Ethernet. Refer to page 396 for details.
Output
The data shown in the table below can be output from PV500 during inspections. “Total Judgement” is output
without condition, however, outputting the other data is selective.
Connector
Terminal Block
Total Judgement
RSLT
RSLT
Scan Count
OUT0-15
OUT0-7
Judgement (JDC)
OUT0-15
OUT0-7
Numerical calculation result
OUT0-15
OUT0-7
To set whether to output or not, select “ENVIRONMENT” > “Input/Output” > “Parallel I/O Output”.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......