-57-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range Note
Group
252
FAN Option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land "On1", 2: Hi-
Land "On2"
-
0 - 2
* Read only
1
SAFETY SWITCH
For test purpose
0
0,3-6
2 FAN MANUAL SWITCH
0: Auto, 1: Manual
0
0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100
0-255
4 FAN2 MANUAL VOLTAGE
100
0-255
5 FAN3 MANUAL VOLTAGE
100
0-255
6 FAN4 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100
0-255
7 FAN5 MANUAL VOLTAGE
100
0-255
8 FAN6 MANUAL VOLTAGE
100
0-255
9 FAN7 MANUAL VOLTAGE
100
0-255
Group
253
Fan Tem Error Setting (Memorized1
(PT-VX500/PT-VW4301
Normal Ceiling
HiLand-
Normal
ON1/
ON2
HiLand-
Ceiling
ON1/
ON2
0 Temp A Warning (High)
9999
-
1 Temp B Warning (High)
9999
-
2 Temp C Warning (High)
9999
-
3 Temp B-A Warning(High)
9999
-
4 Temp C-A Warning(High)
9999
-
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
45
44
39/35
39/36
30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
64
63
54/50
54/51
30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
65
65
56/58
56/59
30-100
8 Temp B-A Warning (Normal) Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
28
28
24/22
24/22
0-100
9 Temp C-A Warning(Normal) Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
21
21
18/16
18/16
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
49
48
39/36
39/37
30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
68
67
53/50
53/50
-
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
65
64
55/57
55/58
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
34
34
27/25
27/25
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
26
26
20/17
20/17
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
5
0-100
17 Temp C Warning Offset
(Temp)
10
0-100
18 Temp B-A Warning Offset
(Temp)
0
0-100
19 Temp C-A Warning Offset
(Temp)
0
0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min
-
ute at the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
3
0-5
21 Temp B Warning Offset
(Time)
3
0-5
22 Temp C Warning Offset
(Time)
3
0-5
23 Temp B-A Warning Offset
(Time)
3
0-5
24 Temp C-A Warning Offset
(Time)
3
0-5
26 Temp A ForceLamp ECO
39
40
37/33
37/34
20-50
27 Temp A ForceLamp ECO EN-
ABLE
1
0-1
Group
254
Fan Control Range Setting (Temp./Voltage1
(PT-VX500/PT-VW4301
Normal Ceiling
HiLand-
Normal
ON1/
ON2
HiLand-
Ceiling
ON1/
ON2
0 Normal Fan Control Min
Temp
30
31
26/26
25/26
20-100
1 Normal Fan Control Max
Temp
38
38
34/32
34/33
20-100
2 Normal Fan1 Min
62
62
82/102 82/102
0-255
Содержание PT-VX500U
Страница 82: ...82 IC Block Diagrams IC Block Diagrams ICL3232ECV RS 232C driver IC3801 CXD3551GG E GAMMA IC501...
Страница 83: ...83 IC Block Diagrams CXA3828GL E S H IC561 TLV320AIC3105 Audio control IC5001...
Страница 84: ...84 IC Block Diagrams PW190 Scaler IC301 TB6608FNG IRIS Driver IC601...
Страница 85: ...85 IC Block Diagrams SSC9512S Power Switching IC604 PIC32MX695F512H Netwrok IC8801...
Страница 86: ...86 IC Block Diagrams TPS54286 DC DC converter IC7811 STR A6079 Power switching IC603...
Страница 116: ......