Chapter 6
Maintenance — Light source/temperature indicators
ENGLISH - 219
Temperature indicator <TEMP>
Indicator status
Status
Solution
Lighting in red
f
Warm-up status
f
Wait five minutes when the power is turned on while the temperature is low
(approximately 0 °C (32 °F)).
f
Install the projector in a location with the operating environment temperature
between 0 °C (32 °F) and 50 °C (122 °F)
*1
.
f
Internal temperature is high
(warning).
f
Remove any objects if they are blocking the air intake/exhaust port.
f
Install the projector in a location with the operating environment temperature
between 0 °C (32 °F) and 50 °C (122 °F)
*1
, and ambient humidity between
10 % and 80 % (no condensation).
Blinking in red
(2 times)
f
Internal temperature is high (standby
status).
Blinking in red
(3 times)
f
The cooling fan has stopped.
f
Turn the <MAIN POWER> switch to <OFF> (
x
page 69), and consult
your dealer.
*1
The operating environment temperature should be between 0 °C (32 °F) and 45 °C (113 °F) if the projector is used at an altitude between 1 400 m
(4 593') and 4 200 m (13 780') above sea level.
Note
f
If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
Содержание PT-RS20K
Страница 58: ...58 ENGLISH Chapter 3 Basic Operations This chapter describes basic operations to start with ...
Страница 193: ...ENGLISH 193 Chapter 5 Operations This chapter describes how to use each function ...
Страница 226: ...226 ENGLISH Chapter 7 Appendix This chapter describes specifications and after sales service for the projector ...